Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer
dc.contributor.author | Goiato, Marcelo Coelho [UNESP] | |
dc.contributor.author | Haddad, Marcela Filie [UNESP] | |
dc.contributor.author | Sinhoreti, Mario A. C. | |
dc.contributor.author | Santos, Daniela Micheline dos [UNESP] | |
dc.contributor.author | Pesqueira, Aldieris Alves [UNESP] | |
dc.contributor.author | Moreno, Amalia [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.date.accessioned | 2013-09-30T18:30:24Z | |
dc.date.accessioned | 2014-05-20T13:43:54Z | |
dc.date.available | 2013-09-30T18:30:24Z | |
dc.date.available | 2014-05-20T13:43:54Z | |
dc.date.issued | 2010-12-16 | |
dc.description.abstract | Background: We evaluated the influence of chemical disinfection and accelerated aging on the dimensional stability and detail reproduction of a silicone elastomer containing one of two opacifiers.Methods: A total of 90 samples were fabricated from Silastic MDX 4-4210 silicone and divided into groups (n = 10) according to opacifier content (barium sulfate or titanium dioxide) and disinfectant solution (neutral soap, Efferdent, or 4% chlorhexidine). The specimens were disinfected 3 times per week during 60 days and then subjected to accelerated aging for 1008 hours. Dimensional stability and detail reproduction tests were performed after specimens' fabrication (baseline), chemical disinfection and periodically during accelerated aging (252, 504, and 1008 hours). The results were analyzed using 3-way repeated-measures ANOVA and the Tukey HSD test (alpha = 0.05).Results: All groups exhibited dimensional changes over time. The opacifier (p = .314), period (p < .0001) and their interactions (p = .0041) affected the dimensional stability of the silicone. Statistical significant dimensional differences occurred between groups with (0.071) and without opacifiers (0.053). Accelerated aging influenced the dimensional stability of the samples. All groups scored 2 in the detail reproduction tests, which represents the fully reproducing of three test grooves with accurate angles.Conclusions: Incorporation of opacifiers alters the dimensional stability of silicones used in facial prosthetics, but seems to have no influence on detail reproduction. Accelerated aging is responsible for most of the dimensional changes in Silastic MDX4 4210, but all dimensional changes measured in this study remained within the limits of stability necessary for this application. | en |
dc.description.affiliation | UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil | |
dc.description.affiliation | Univ Estadual Campinas, UNICAMP, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, BR-13414903 Piracicaba, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 08/52766-9 | |
dc.format.extent | 9 | |
dc.identifier | http://dx.doi.org/10.1186/1475-925X-9-85 | |
dc.identifier.citation | Biomedical Engineering Online. London: Biomed Central Ltd., v. 9, p. 9, 2010. | |
dc.identifier.doi | 10.1186/1475-925X-9-85 | |
dc.identifier.file | WOS000285715100001.pdf | |
dc.identifier.issn | 1475-925X | |
dc.identifier.lattes | 9719883814872582 | |
dc.identifier.orcid | 0000-0002-3800-3050 | |
dc.identifier.uri | http://hdl.handle.net/11449/15358 | |
dc.identifier.wos | WOS:000285715100001 | |
dc.language.iso | eng | |
dc.publisher | Biomed Central Ltd. | |
dc.relation.ispartof | Biomedical Engineering Online | |
dc.relation.ispartofjcr | 1.676 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Web of Science | |
dc.title | Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer | en |
dc.type | Artigo | pt |
dcterms.license | http://www.biomedcentral.com/about/license | |
dcterms.rightsHolder | Biomed Central Ltd. | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 9719883814872582 | |
unesp.author.lattes | 2336450644149867[5] | |
unesp.author.orcid | 0000-0002-3800-3050[1] | |
unesp.author.orcid | 0000-0003-3020-5253[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- WOS000285715100001.pdf
- Tamanho:
- 775.48 KB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: