Logotipo do repositório
 

Publicação:
Analysis of the biomechanical behavior of short implants: the photo-elasticity method

dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorMello, Caroline Cantieri de[UNESP]
dc.contributor.authorSantiago Junior, Joel Ferreira [UNESP]
dc.contributor.authorSouza Batista, Victor Eduardo de [UNESP]
dc.contributor.authorde Faria Almeida, Daniel Augusto [UNESP]
dc.contributor.authorVerri, Fellippo Ramos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade do Sagrado Coração (USC)
dc.date.accessioned2015-12-07T15:38:46Z
dc.date.available2015-12-07T15:38:46Z
dc.date.issued2015-10-01
dc.description.abstractThe aim of this study was to analyze the stress distribution of short implants supporting single unit or splinted crowns by the photo-elasticity method. Four photo-elastic models were produced: A (3.75×7mm); B (3.75×7mm, 3.75×7mm and 3.75×7mm); C (3.75×10mm, 3.75×7mm and 3.75×7mm); D (3.75×13mm, 3.75×7mm and 3.75×7mm). The prostheses were made with Ni-Cr alloy. A load of 100N in the axial and oblique directions was applied, totaling 380 applications, individually capturing their images in each model. The data were randomized and analyzed qualitatively and quantitatively by 2 examiners. The oblique loading was significantly more damaging. The increase in length was favorable for stress distribution (p<0.05). The splinting was beneficial for the transmission of stresses mainly (p<0.05). The splinting of the crowns, as well as increasing the length of the first implant and axial loading was most beneficial in the stress distribution. Short splinted implants behaved better than single unit implants. Increasing of the length of the first implant significantly improved the stress distribution in all analyzed situations.en
dc.description.affiliationUniversity of Sacred Heart — USC, Department of Health Sciences, São Paulo, Brazil
dc.description.affiliationUnespAraçatuba Dental School, UNESP — Univ Estadual Paulista, Campus of Araçatuba, Department of Dental Materials and Prosthodontics, Araçatuba, São Paulo, Brazil
dc.format.extent187-192
dc.identifierhttp://dx.doi.org/10.1016/j.msec.2015.05.024
dc.identifier.citationMaterials Science & Engineering. C, Materials For Biological Applications, v. 55, p. 187-192, 2015.
dc.identifier.doi10.1016/j.msec.2015.05.024
dc.identifier.issn1873-0191
dc.identifier.lattes5581364193525500
dc.identifier.pubmed26117754
dc.identifier.urihttp://hdl.handle.net/11449/131617
dc.language.isoeng
dc.publisherElsevier B. V.
dc.relation.ispartofMaterials Science & Engineering. C, Materials For Biological Applications
dc.relation.ispartofsjr1,110
dc.rights.accessRightsAcesso restritopt
dc.sourcePubMed
dc.subjectDental implantsen
dc.subjectDental prosthesis, implant-supporteden
dc.subjectDental stress analysisen
dc.titleAnalysis of the biomechanical behavior of short implants: the photo-elasticity methoden
dc.typeArtigopt
dcterms.rightsHolderElsevier B. V.
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5581364193525500
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos