Logotipo do repositório
 

Publicação:
Orientation and calibration requirements for hyperpectral imaging using UAVS: A case study

dc.contributor.authorTommaselli, A. M.G. [UNESP]
dc.contributor.authorBerveglieri, A. [UNESP]
dc.contributor.authorOliveira, R. A. [UNESP]
dc.contributor.authorNagai, L. Y. [UNESP]
dc.contributor.authorHonkavaara, E.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionFinnish Geospatial Research Institute FGI
dc.date.accessioned2018-12-11T16:42:12Z
dc.date.available2018-12-11T16:42:12Z
dc.date.issued2016-03-17
dc.description.abstractFlexible tools for photogrammetry and remote sensing using unmanned airborne vehicles (UAVs) have been attractive topics of research and development. The lightweight hyperspectral camera based on a Fabry-Pérot interferometer (FPI) is one of the highly interesting tools for UAV based remote sensing for environmental and agricultural applications. The camera used in this study acquires images from different wavelengths by changing the FPI gap and using two CMOS sensors. Due to the acquisition principle of this camera, the interior orientation parameters (IOP) of the spectral bands can vary for each band and sensor and changing the configuration also would change these sets of parameters posing an operational problem when several bands configurations are being used. The objective of this study is to assess the impact of use IOPs estimated for some bands in one configuration for other bands of different configuration the FPI camera, considering different IOP and EOP constraints. The experiments were performed with two FPI-hyperspectral camera data sets: the first were collected 3D terrestrial close-range calibration field and the second onboard of an UAV in a parking area in the interior of São Paulo State.en
dc.description.affiliationUniv Estadual Paulista Unesp
dc.description.affiliationFinnish Geospatial Research Institute FGI
dc.description.affiliationUnespUniv Estadual Paulista Unesp
dc.description.sponsorshipAcademy of Finland
dc.description.sponsorshipIdAcademy of Finland: 273806
dc.format.extent109-115
dc.identifierhttp://dx.doi.org/10.5194/isprsarchives-XL-3-W4-109-2016
dc.identifier.citationInternational Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences - ISPRS Archives, v. 40, n. 3W4, p. 109-115, 2016.
dc.identifier.doi10.5194/isprsarchives-XL-3-W4-109-2016
dc.identifier.file2-s2.0-84964871607.pdf
dc.identifier.issn1682-1750
dc.identifier.scopus2-s2.0-84964871607
dc.identifier.urihttp://hdl.handle.net/11449/168614
dc.language.isoeng
dc.relation.ispartofInternational Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences - ISPRS Archives
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectGeometric calibration
dc.subjectHyperspectral frame cameras
dc.subjectTwo sensors camera
dc.titleOrientation and calibration requirements for hyperpectral imaging using UAVS: A case studyen
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.author.lattes5493428631948910[1]
unesp.author.orcid0000-0003-0483-1103[1]

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84964871607.pdf
Tamanho:
983.7 KB
Formato:
Adobe Portable Document Format
Descrição:

Coleções