Competitive Host-guest Electrochemical Detection of Ivermectin Drug Using a β-cyclodextrin/Graphene-based Electrode
| dc.contributor.author | Silva, Martin K. L. [UNESP] | |
| dc.contributor.author | Simões, Rafael P. [UNESP] | |
| dc.contributor.author | Leão, Alcides L. [UNESP] | |
| dc.contributor.author | Lapa, Rainer M. L. | |
| dc.contributor.author | Rascón, Jesús | |
| dc.contributor.author | Cesarino, Ivana [UNESP] | |
| dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
| dc.contributor.institution | Instituto de Investigación en Ganadería y Biotecnología (IGBI) | |
| dc.contributor.institution | Facultad de Ciencias de la Salud (FACISA) | |
| dc.contributor.institution | Instituto de Investigación para el Desarrollo Sustentable de Ceja de Selva (INDES-CES) | |
| dc.date.accessioned | 2023-03-01T20:04:05Z | |
| dc.date.available | 2023-03-01T20:04:05Z | |
| dc.date.issued | 2022-01-01 | |
| dc.description.abstract | The present study describes the novel development and application of an ivermectin (IVM) sensing electrochemical platform based on reduced graphene oxide (rGO) and the macrocyclic host β-cyclodextrin (β-CD) molecule. The sensing method was based in the host-guest characteristics of β-CD and competitive interaction between the target analyte and the methylene blue (MB) redox probe. Differential pulse voltammetry (DPV) was employed for the detection of IVM and a linear response between 0.5 and 40.0 μmol L−1 with a limit of detection of 0.25 μmol L−1 was obtained using the glassy carbon (GC)/rGO/β-CD electrode. The sensing platform was successfully applied for the detection of IVM in tap water samples, which may expand the applications of β-CD towards the analysis of other chemical species. | en |
| dc.description.affiliation | São Paulo State University (UNESP) School of Agriculture, Avenida Universitária, n° 3780 | |
| dc.description.affiliation | Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas (UNTRM) Instituto de Investigación en Ganadería y Biotecnología (IGBI), Amazonas | |
| dc.description.affiliation | Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas (UNTRM) Facultad de Ciencias de la Salud (FACISA), Amazonas | |
| dc.description.affiliation | Universidad Nacional Toribio Rodríguez de Mendoza de Amazonas (UNTRM) Instituto de Investigación para el Desarrollo Sustentable de Ceja de Selva (INDES-CES), Amazonas | |
| dc.description.affiliationUnesp | São Paulo State University (UNESP) School of Agriculture, Avenida Universitária, n° 3780 | |
| dc.identifier | http://dx.doi.org/10.1002/elan.202100649 | |
| dc.identifier.citation | Electroanalysis. | |
| dc.identifier.dimensions | pub.1147933155 | |
| dc.identifier.doi | 10.1002/elan.202100649 | |
| dc.identifier.issn | 1521-4109 | |
| dc.identifier.issn | 1040-0397 | |
| dc.identifier.orcid | 0000-0002-2879-5138 | |
| dc.identifier.orcid | 0000-0002-2296-3671 | |
| dc.identifier.orcid | 0000-0003-4381-8104 | |
| dc.identifier.orcid | 0000-0003-2410-9716 | |
| dc.identifier.orcid | 0000-0002-3433-8574 | |
| dc.identifier.orcid | 0000-0002-9305-7203 | |
| dc.identifier.scopus | 2-s2.0-85131013655 | |
| dc.identifier.uri | http://hdl.handle.net/11449/240158 | |
| dc.language.iso | eng | |
| dc.publisher | Wiley | |
| dc.relation.ispartof | Electroanalysis | |
| dc.rights.accessRights | Acesso aberto | pt |
| dc.rights.sourceRights | oa_all | |
| dc.rights.sourceRights | green | |
| dc.source | Scopus | |
| dc.source | Dimensions | |
| dc.subject | Electrochemical sensors | |
| dc.subject | Graphene | |
| dc.subject | Host-guest interaction | |
| dc.subject | Ivermectin | |
| dc.subject | β-Cyclodextrin | |
| dc.title | Competitive Host-guest Electrochemical Detection of Ivermectin Drug Using a β-cyclodextrin/Graphene-based Electrode | en |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication | |
| relation.isOrgUnitOfPublication | ef1a6328-7152-4981-9835-5e79155d5511 | |
| relation.isOrgUnitOfPublication.latestForDiscovery | ef1a6328-7152-4981-9835-5e79155d5511 | |
| unesp.author.orcid | 0000-0002-2296-3671[6] | |
| unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Ciências Agronômicas, Botucatu | pt |

