Publicação: Comparison of high performance liquid chromatography and three titrimetric methods for the determination of ceftazidime in pharmaceutical formulations
dc.contributor.author | Moreno, Andréia de Haro [UNESP] | |
dc.contributor.author | Salgado, Hérida Regina Nunes [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2016-01-28T16:56:36Z | |
dc.date.available | 2016-01-28T16:56:36Z | |
dc.date.issued | 2012 | |
dc.description.abstract | Three different assays for the quality control of ceftazidime in commercial formulations were developed and compared: acidimetric, iodometric and nonaqueous methods. Method validation yielding good results and included precision and accuracy, with good recovery percent ranged from 99.67 to 100.39, and R.S.D. values smaller than 2%. Results were compared to those obtained by high performance liquid chromatographic method, developed and published previously by us, and no evidence of significant difference was observed. The results obtained agreed well with the contents stated on the labels, being rapid, simple and inexpensive alternative method for the determination of ceftazidime in pharmaceutical formulations. | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Farmacos e Médicamentos, Faculdade de Ciências Farmacêuticas de Araraquara, Araraquara, Rodovia Araraquara-Jaú, km1, Campus, CEP 14801-902, SP, Brasil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Farmacos e Médicamentos, Faculdade de Ciências Farmacêuticas de Araraquara, Araraquara, Rodovia Araraquara-Jaú, km1, Campus, CEP 14801-902, SP, Brasil | |
dc.description.sponsorship | Fundação para o Desenvolvimento da UNESP (FUNDUNESP) | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 6-13 | |
dc.identifier | http://dx.doi.org/10.5923/j.aac.20120203.01 | |
dc.identifier.citation | Advances in Analytical Chemistry, v. 2, n. 3, p. 6-13, 2012. | |
dc.identifier.doi | 10.5923/j.aac.20120203.01 | |
dc.identifier.issn | 2163-2847 | |
dc.identifier.lattes | 9048202968088646 | |
dc.identifier.lattes | 9881720291571774 | |
dc.identifier.uri | http://hdl.handle.net/11449/133788 | |
dc.language.iso | eng | |
dc.publisher | Scientific & Academic Publishing | |
dc.relation.ispartof | Advances in Analytical Chemistry | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Currículo Lattes | |
dc.subject | Ceftazidime | en |
dc.subject | HPLC | en |
dc.subject | Method comparison | en |
dc.subject | Pharmaceutical analysis | en |
dc.subject | Quality control | en |
dc.subject | Titrimetry | en |
dc.title | Comparison of high performance liquid chromatography and three titrimetric methods for the determination of ceftazidime in pharmaceutical formulations | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | e214da1b-9929-4ae9-b8fd-655e9bfeda4b | |
relation.isDepartmentOfPublication.latestForDiscovery | e214da1b-9929-4ae9-b8fd-655e9bfeda4b | |
relation.isOrgUnitOfPublication | 95697b0b-8977-4af6-88d5-c29c80b5ee92 | |
relation.isOrgUnitOfPublication.latestForDiscovery | 95697b0b-8977-4af6-88d5-c29c80b5ee92 | |
unesp.author.lattes | 9048202968088646 | |
unesp.author.lattes | 9881720291571774 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquara | pt |
unesp.department | Fármacos e Medicamentos - FCF | pt |