Validation of a stability-indicating HPLC method with diode array detection for the determination of beclomethasone dipropionate in aqueous suspension for nebulizer

dc.contributor.authorSouza, Ana Luiza Ribeiro de [UNESP]
dc.contributor.authorAzevedo, Cintia
dc.contributor.authorMadeira, Kelly
dc.contributor.authorMoreira, Simone
dc.contributor.authorChorilli, Marlus [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Metodista de Piracicaba (UNIMEP)
dc.date.accessioned2016-01-28T16:56:40Z
dc.date.available2016-01-28T16:56:40Z
dc.date.issued2013
dc.description.abstractThe aim of this study was to develop and validate a stability-indicating high performance liquid chromatographic method for the analysis of beclomethasone dipropionate in aqueous suspensions for nebulizer. This drug was submitted to accelerated degradation studies under acidic, alkaline and oxidation conditions, exposure to light and moisture and thermal stability. The separation of BD and its degradation products was achieved on Eclipse XDB Phenyl column (150 nn x 4.6 mm, i. d. 5 µm particle size) with an isocratic mobile phase containing methanol and water (80:20, v/v). The flow rate was 1.0 mL min-1 and detection wavelength was set at 240 nm, at 30 ºC. Different degradation products were formed in the stress conditions and the peak purity indexes of BD obtained by diode array detection were > 0.999, confirming the specificity of this method. The calibration curve was linear over the selected concentration range of 30.36 – 91.07 µg mL-1 with a correlation coefficient 0.99989. Recovery was within acceptable statistical limits and the limit of detection was 0.062 µg mL-1 . The intra-day repeatability and intermediate precision (RSD) amongst six sample preparations was 1.60 % and 1.43 %, respectively. In conclusion, the proposed method was found to be rapid and stability-indicating with adequate specificity, precision, accuracy and robustness and hence be suitable for monitoring the degradation process of BD during stability studies.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Fármacos e Medicamentos, Faculdade de Ciências Farmacêuticas de Araraquara, Araraquara, Rodovia Araraquara-Jaú, km 1, Campus, CEP 14081-902, SP, Brasil
dc.description.affiliationFaculty of Health Sciences, Methodist University of Piracicaba, Piracicaba, Brazil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Fármacos e Medicamentos, Faculdade de Ciências Farmacêuticas de Araraquara, Araraquara, Rodovia Araraquara-Jaú, km 1, Campus, CEP 14081-902, SP, Brasil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent4-9
dc.identifierhttp://www.jbiopharm.com/index.php/ajbps/article/view/171
dc.identifier.citationAsian Journal of Biomedical & Pharmaceutical Sciences, v. 3, n. 19, p. 4-9, 2013.
dc.identifier.doi10.15272/ajbps.v3i19.171
dc.identifier.issn2249-622X
dc.identifier.lattes1427125996716282
dc.identifier.lattes1427125996716282
dc.identifier.urihttp://hdl.handle.net/11449/133802
dc.language.isoeng
dc.relation.ispartofAsian Journal of Biomedical & Pharmaceutical Sciences
dc.rights.accessRightsAcesso restrito
dc.sourceCurrículo Lattes
dc.subjectBeclomethasone dipropionateen
dc.subjectDiode array detectionen
dc.subjectMethod developmenten
dc.subjectStability-indicating HPLCen
dc.subjectStress degradation studiesen
dc.titleValidation of a stability-indicating HPLC method with diode array detection for the determination of beclomethasone dipropionate in aqueous suspension for nebulizeren
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes1427125996716282
unesp.author.lattes1427125996716282
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquarapt
unesp.departmentFármacos e Medicamentos - FCFpt

Arquivos