The effect of polymerization mode on monomer conversion, free radical entrapment, and interaction with hydroxyapatite of commercial self-adhesive cements

Nenhuma Miniatura disponível

Data

2015-06-01

Autores

D'Alpinoa, Paulo Henrique Perlatti
Silva, Marilia Santos
Vismara, Marcus Vinicius Goncalves[UNESP]
Di Hipolito, Vinicius
Miranda Gonzalez, Alejandra Hortencia
Graeff, Carlos Frederico de Oliveira [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Elsevier B.V.

Resumo

Objectives: This study evaluated the degree of conversion, the free radical entrapment, and the chemical interaction of self-adhesive resin cements mixed with pure hydroxyapatite, as a function of the polymerization activation mode among a variety of commercial self-adhesive cements.Materials and methods: Four cements (Embrace WetBond, MaxCem Elite, Bifix SE, and RelyX U200) were mixed, combined with hydroxyapatite, dispensed into molds, and distributed into three groups, according to polymerization protocols: IP (photoactivation for 40 s); DP (delayed photoactivation, 10 min self-curing plus 40 s light-activated); and CA (chemical activation, no light exposure). Infrared (IR) spectra were obtained and monomer conversion (%) was calculated by comparing the aliphatic-to-aromatic IR absorption peak ratio before and after polymerization (n=10). The free radical entrapment values of the resin cements were characterized using Electron Paramagnetic Resonance (EPR) and the concentration of spins (number of spins/mass) calculated (n=3). Values were compared using two-way ANOVA and Tukey's post-hoc test (alpha=5%). X-ray diffraction (XRD) characterized the crystallinity of hydroxyapatite as a function of the chemical interactions with the resin cements.Results: The tested parameters varied as a function of resin cement and polymerization protocol. Embrace WetBond and RelyX U200 demonstrated dependence on photoactivation (immediate or delayed), whereas MaxCem Elite exhibited dependence on the chemical activation mode. Bifix SE presented the best balance based on the parameters analyzed, irrespective of the activation protocol.Conclusions: Choice of polymerization protocol affects the degree of conversion, free radical entrapment, and the chemical interaction between hydroxyapatite and self-adhesive resin cement mixtures. (C) 2015 Elsevier Ltd. All rights reserved.

Descrição

Palavras-chave

Self-adhesive resin cement, Hydroxyapatite, Chemical interaction, FT-IR, EPR, X-ray diffraction

Como citar

Journal Of The Mechanical Behavior Of Biomedical Materials, v. 46, p. 83-92, 2015.