Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2025 a 4 de janeiro de 2026.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

Logo do repositório

Comparison of the Stability of Mandibular Sagittal Osteotomy Fixation between Two Types of Titanium Miniplates: A Biomechanical Study in Sheep Mandibles

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Thieme Medical Publ Inc

Tipo

Artigo

Direito de acesso

Acesso restrito

Resumo

This study aimed to compare the biomechanical stability of the fixation of mandibular sagittal split osteotomy of the ramus by two types of titanium miniplates in sheep mandibles. Seven preserved sheep mandibles with similar weight and size were selected, dissected with complete removal of soft-tissue structures, and sectioned in their midline. After performing sagittal split osteotomy, 5mm of advancement was standardized and samples were divided into two groups according to the type of titanium miniplate (GI = seven hemimandibles were fixed with straight titanium miniplate, GII = seven hemimandibles were fixed with L-shaped titanium miniplates), and then subjected to compressive load. The means (standard deviation) of the compressive load and extension values were 70.68 N (22.26) and 63.36 mm (15.60) to straight miniplates, and 78.80 N (32.54) and 70.55 mm (5.42) to L-shaped miniplates. After comparison and statistical analysis, the results showed no significant difference between the two types of titanium miniplates.

Descrição

Palavras-chave

osteotomy, sagittal split ramus, orthognathic surgery

Idioma

Inglês

Citação

Craniomaxillofacial Trauma & Reconstruction. New York: Thieme Medical Publ Inc, v. 11, n. 2, p. 114-117, 2018.

Itens relacionados

Financiadores

Coleções

Unidades

Departamentos

Cursos de graduação

Programas de pós-graduação

Outras formas de acesso