A simple procedure to obtain nanodiamonds from leftover of HFCVD system for biological application

Nenhuma Miniatura disponível

Data

2020-03-01

Autores

Hurtado, Carolina Ramos
Wachesk, Cristiane da Costa
Queiroz, Rafaela Campos
Macedo, Erenilda Ferreira de
Borja de Oliveira Correia, Rebeca Falcao
Taiariol, Thalita Sani
Diniz, Milton Faria
Isaias dos Santos, Alexandre Martins
Amaral Montanheiro, Thais Larissa do
Hurtado, Gabriela Ramos [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Springer

Resumo

Nanodiamonds (NDs) are amongst the most investigated carbon-based nanostructures due to their chemical stability and favorable mechanical properties. Despite the number of works on methods for NDs production, one of the main challenges is to achieve their colloidal stability in aqueous suspension. Additionally, NDs are normally obtained by expensive, complex and time-consuming process. Herein, it was presented a facile method to obtain NDs in aqueous suspension by using columnar structure diamond from Hot-Filament Chemical Vapour Deposition reactor (HFCVD). CVD diamond leftover thick film from CVDVale Company was used. Therefore, this method has the advantage of being not only practical but also cost-effective since it brings a profitable use of CVD diamond leftover. The Diamond thick film was submitted to ultrasonic cavitation in the presence and absence of ZrO2 microbeads in aqueous medium. The NDs hydrodynamic diameter and the stability in aqueous suspension were monitored by light scattering, size and morphology were analyzed by transmission electronic microscopy. Considering the wide application of NDs in biomedical devices, cytotoxicity of aqueous suspensions of NDs was evaluated against murine embryonic fibroblast cells. Furthermore, NDs were functionalized with hydrogen and carboxyl groups. NDs aqueous suspension of straight size distribution was obtained even in the absence of ZrO2 beads, indicating that they may be dispensable in order to decrease NDs size. NDs of average hydrodynamic diameter of 22 nm and -35 mV of Zeta-potential were obtained after ultrasonic cavitation followed by 2 h of centrifugation, not demonstrating cytotoxicity to cells at very low (0.05-0.5 mu g/mL) nor at higher concentrations (116 mu g/mL). Nevertheless, NDs showed a moderate cytotoxicity at intermediary concentration range (0.5-2.2 mu g/mL). From our knowledge, this is the first work that reports on a facile method for providing NDs aqueous suspension with high colloidal stability from HFCVD diamond leftover.

Descrição

Palavras-chave

Nanodiannonds, Ultrasonic cavitation, CVD diamond, Functionalization, Cytotoxicity, Colloidal suspension

Como citar

Sn Applied Sciences. Cham: Springer International Publishing Ag, v. 2, n. 3, 14 p., 2020.