Show simple item record

dc.contributor.authorCavalcanti, B. N.
dc.contributor.authorOtani, C.
dc.contributor.authorRode, S. M.
dc.date.accessioned2014-05-20T15:28:43Z
dc.date.available2014-05-20T15:28:43Z
dc.date.issued2002-02-01
dc.identifierhttp://dx.doi.org/10.1067/mpr.2002.120655
dc.identifier.citationJournal of Prosthetic Dentistry. St Louis: Mosby, Inc., v. 87, n. 2, p. 158-161, 2002.
dc.identifier.issn0022-3913
dc.identifier.urihttp://hdl.handle.net/11449/38476
dc.description.abstractStatement of problem. Cavity and tooth preparations generate heat because the use of rotary cutting instruments on dental tissues creates friction. Dental pulps cannot survive temperature increases greater than 5.5degreesC.Purpose. This study evaluated the efficiency of 3 different water flows for 2 different tooth preparation techniques to determine which are safe for use.Material and methods. Thermocouples were placed in the pulpal chambers of 30 bovine teeth, and 1 of 2 tooth preparation techniques was used: a low-load intermittent tooth preparation technique or a high-load tooth preparation technique without intervals. Water flows of 0, 30, and 45 mL/min were associated with each technique, for a total of 6 different groups. The results were analyzed with a 2-factor analysis of variance (P<.05).Results. Temperature increases with the high-load technique were 16.40&DEG;C without cooling (group 1), 11.68&DEG;C with 30 mL/min air-water spray cooling (group III), and 9.96&DEG;C with 45 mL/min cooling (group V). With the low-load tooth preparation technique, a 9.54&DEG;C increase resulted with no cooling (group II), a 1.56&DEG;C increase with 30 mL/min air-water spray cooling (group TV), and a 0.04&DEG;C decrease with 45 mL/min cooling (group VI). The low-load technique was associated with more ideal temperature changes.Conclusion. The results of this study confirm the necessity of using a low-load technique and water coolants during cavity and tooth preparation procedures.en
dc.format.extent158-161
dc.language.isoeng
dc.publisherMosby, Inc
dc.relation.ispartofJournal of Prosthetic Dentistry
dc.sourceWeb of Science
dc.titleHigh-speed cavity preparation techniques with different water flowsen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderMosby, Inc
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionInstituto Tecnológico de Aeronáutica (ITA)
dc.description.affiliationUNESP, Sch Dent, Dept Dent Mat & Prosthet, Master Sci Program, São Paulo, Brazil
dc.description.affiliationTechnol Inst Aeronaut, Dept Phys, São Paulo, Brazil
dc.description.affiliationUnespUNESP, Sch Dent, Dept Dent Mat & Prosthet, Master Sci Program, São Paulo, Brazil
dc.identifier.doi10.1067/mpr.2002.120655
dc.identifier.wosWOS:000174270900010
dc.rights.accessRightsAcesso restrito
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt
dc.identifier.lattes9633326235160414
dc.identifier.lattes3422118958429909
unesp.author.lattes9633326235160414
unesp.author.lattes3422118958429909
unesp.author.orcid0000-0002-4261-4217[3]
dc.relation.ispartofjcr2.347
dc.relation.ispartofsjr1,087
Localize o texto completo

Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record