Efficacy of ultrasonic, electric and manual toothbrushes in patients with fixed orthodontic appliances

Nenhuma Miniatura disponível

Data

2007-03-01

Autores

Costa, Mauricio Ribeiro [UNESP]
Silva, Vanessa Camila [UNESP]
Miqui, Miriam Nakatani
Sakima, Tatsuko
Spolidório, Denise Madalena Palomari [UNESP]
Cirelli, Joni Augusto [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Resumo

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Descrição

Palavras-chave

Electric toothbrushes, Fixed orthodontic appliance, Oral hygiene, Streptococcus mutans, adolescent, bacterial count, child, clinical trial, controlled clinical trial, controlled study, electricity, epidemiology, female, human, instrumentation, male, microbiology, orthodontic device, randomized controlled trial, saliva, tooth brushing, tooth plaque, ultrasound therapy, Adolescent, Child, Colony Count, Microbial, Dental Plaque, Electricity, Epidemiologic Methods, Female, Humans, Male, Orthodontic Appliances, Saliva, Toothbrushing, Ultrasonic Therapy

Como citar

Angle Orthodontist, v. 77, n. 2, p. 361-366, 2007.