Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Comparison of simulated periodontal bone defect depth measured in digital radiographs in dedicated and non-dedicated software systems

dc.contributor.authorScaf, Gulnara [UNESP]
dc.contributor.authorSakakura, C. E.
dc.contributor.authorKalil, P. F. D.
dc.contributor.authorde Morais, J. A. N. Dearo
dc.contributor.authorLoffredo, L. C. M.
dc.contributor.authorWenzel, A.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Aarhus
dc.date.accessioned2014-05-20T15:23:13Z
dc.date.available2014-05-20T15:23:13Z
dc.date.issued2006-11-01
dc.description.abstractObjectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.en
dc.description.affiliationState Univ São Paulo, Araraquara Dent Sch, Dept Oral Diag & Surg, São Paulo, Brazil
dc.description.affiliationState Univ São Paulo, Araraquara Dent Sch, Dept Social Dent, São Paulo, Brazil
dc.description.affiliationUniv Aarhus, Sch Dent, Fac Hlth Sci, Dept Oral Radiol, Aarhus, Denmark
dc.description.affiliationUnespState Univ São Paulo, Araraquara Dent Sch, Dept Oral Diag & Surg, São Paulo, Brazil
dc.description.affiliationUnespState Univ São Paulo, Araraquara Dent Sch, Dept Social Dent, São Paulo, Brazil
dc.format.extent422-425
dc.identifierhttp://dx.doi.org/10.1259/dmfr/61300663
dc.identifier.citationDentomaxillofacial Radiology. London: British Inst Radiology, v. 35, n. 6, p. 422-425, 2006.
dc.identifier.doi10.1259/dmfr/61300663
dc.identifier.fileWOS000242714200006.pdf
dc.identifier.issn0250-832X
dc.identifier.urihttp://hdl.handle.net/11449/34053
dc.identifier.wosWOS:000242714200006
dc.language.isoeng
dc.publisherBritish Inst Radiology
dc.relation.ispartofDentomaxillofacial Radiology
dc.relation.ispartofjcr1.848
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectdigital radiographypt
dc.subjectalveolar bone losspt
dc.subjectmeasurementpt
dc.titleComparison of simulated periodontal bone defect depth measured in digital radiographs in dedicated and non-dedicated software systemsen
dc.typeArtigo
dcterms.licensehttp://www.birjournals.org/site/policy/licence.xhtml
dcterms.rightsHolderBritish Inst Radiology
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt
unesp.departmentOdontologia Social - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000242714200006.pdf
Tamanho:
98.06 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: