Restaurações endocrown em pré-molares: influência das paredes remanescentes da estrutura dentária e materiais restauradores na resistência à fadiga
dc.contributor.advisor | Melo, Renata Marques de Melo [Unesp] | |
dc.contributor.author | Mohidin Demachkia, Amir | |
dc.contributor.coadvisor | João Paulo Mendes Tribst | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2023-09-01T11:34:54Z | |
dc.date.available | 2023-09-01T11:34:54Z | |
dc.date.issued | 2023-06-06 | |
dc.description.abstract | Este estudo teve como objetivo avaliar o efeito da estrutura dentária remanescente e dois materiais diferentes de restauração CAD/CAM no desempenho à fadiga e no modo de falha de pré-molares tratados endodonticamente restaurados por endocrowns. Um total de 90 pré-molares superiores foram tratados endodonticamente e divididos aleatoriamente de acordo com o número de paredes axiais remanescentes, e os materiais restauradores foram divididos em 6 grupos (n = 15); quatro paredes restantes restauradas com zircônia ultratranslúcida 5Y-PSZ (grupo Fo-Z) e dissilicato de lítio (grupo Fo-L), três paredes restantes restauradas com 5Y-PSZ (grupo Th-Z) e dissilicato de lítio (grupo Th-L) e duas paredes restantes restauradas com 5Y- PSZ (grupo Tw-Z) e dissilicato de lítio (Tw-L). As restaurações foram cimentadas adesivamente e os espécimes foram submetidos a cargas de fadiga gradual em seu longo eixo (carga inicial: 200 N, frequência: 20 Hz). Uma carga incremental de 100 N por 10.000 ciclos foi aplicada com um pistão metálico de Ø 6 mm até a falha. A carga de falha por fadiga (FFL) e o número de ciclos de falha (CFF) no momento da falha foram registrados e analisados estatisticamente por ANOVA 2 fatores e teste de Kaplan-Meier (α = 0,05). Os espécimes fraturados foram examinados em estereomicroscópio em 8× e 25× e os modos de falha foram determinados como reparáveis ou catastróficos. FFL e CFF foram significativamente influenciados pelo material restaurador (p < 0,05). As restaurações de 5Y-PSZ apresentaram FFL (Fo-Z = 1487 N, Tw-Z = 1427 N, Tw-Z = 1533 N) e probabilidade de sobrevivência significativamente maiores quando comparadas com dissilicato de lítio (Fo-L = 1060 N, Th-L = 940 N, Tw-L = 1000 N). O número de paredes remanescentes não afetou o comportamento de fadiga ou modo de falha dos corpos de prova. Das restaurações de dissilicato de lítio, 51% tiveram falhas reparáveis, enquanto 95% das restaurações de zircônia ultratranslúcida 5Y-ZP tiveram falhas catastróficas. Endocrowns de zircônia apresentaram melhor desempenho em fadiga do que endocrowns de dissilicato de lítio, independentemente do número de paredes remanescentes do eixo. Endocrowns de pré-molares de dissilicato de lítio e 5Y-PSZ apresentaram maior FFL do que as cargas mastigatórias normais. | pt |
dc.description.abstract | This study aimed to evaluate the effect of the remaining tooth structure and two different CAD/CAM restoration materials on the fatigue performance and failure mode of endodontically treated premolars restored with endocrowns. A total of 90 maxillary premolars were endodontically treated and divided randomly according to the number of remaining axial walls, and the restorative materials were divided into 6 groups (n = 15); four remaining walls restored with ultratranslucent zirconia 5Y-PSZ (group Fo-Z) and lithium disilicate (group Fo-L), three remaining walls restored with 5Y-PSZ (group Th-Z) and lithium disilicate (Group Th-L), and two remaining walls restored with 5Y-PSZ (group Tw-Z) and lithium disilicate (Tw-L). The restorations were cemented adhesively and the specimens were subjected to stepwise fatigue loading along the long axis (initial load: 200 N, frequency: 20 Hz). An incremental step load of 100 N per 10,000 cycles was applied with a Ø6-mm metallic piston until failure. The fatigue failure load (FFL) and number of failure cycles (CFF) at the time of failure were recorded and statistically analyzed with two-way ANOVA and the Kaplan-Meier test (α = 0.05). Fractured specimens were examined under a stereomicroscope at 8× and 25× and failure modes determined as reparable or catastrophic. FFL and CFF were significantly influenced by restorative material (p < 0.05). 5Y-PSZ endocrowns showed significantly higher FFL (Fo-Z = 1487 N, Th-Z = 1427 N, Tw-Z = 1533 N) and survival probability when compared with lithium disilicate (Fo-L = 1060 N, Th-L = 940 N, Tw-L = 1000 N). The number of remaining walls did not affect the fatigue behavior or failure mode of the specimens. Of the lithium disilicate restorations, 51% had repairable failures, while 95% of ultratranslucent zirconia 5Y-ZP restorations had catastrophic failures. Zirconia endocrowns showed better fatigue performance than lithium disilicate endocrowns, regardless of the number of remaining axis walls. Lithium disilicate and 5Y-PSZ premolar endocrowns showed higher FFL than the normal masticatory loads. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorshipId | 888.595423/2020-00 | |
dc.identifier.capes | 33004145070P8 | |
dc.identifier.uri | http://hdl.handle.net/11449/250562 | |
dc.language.iso | eng | |
dc.publisher | Universidade Estadual Paulista (Unesp) | |
dc.rights.accessRights | Acesso restrito | |
dc.subject | Cerâmicas | pt |
dc.subject | CAD/CAM | pt |
dc.subject | Fadiga | pt |
dc.subject | Falha de restaurações dentarias | pt |
dc.subject | Análise de elementos finitos | pt |
dc.subject | Ceramics | en |
dc.subject | CAD/CAM | en |
dc.subject | Fatigue | en |
dc.subject | Dental restoration failures | en |
dc.subject | Finite element analysis | en |
dc.title | Restaurações endocrown em pré-molares: influência das paredes remanescentes da estrutura dentária e materiais restauradores na resistência à fadiga | pt |
dc.title.alternative | Endocrown restorations in premolars: influence of remaining axial walls of tooth structure and restorative materials on fatigue resistance | en |
dc.type | Tese de doutorado | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.embargo | 24 meses após a data da defesa | pt |
unesp.examinationboard.type | Banca pública | pt |
unesp.graduateProgram | Odontologia Restauradora - ICT | pt |
unesp.knowledgeArea | Prótese dentária | pt |
unesp.researchArea | Desempenho de materiais reabilitadores protéticos | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 3.05 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: