Publicação:
COMPARATIVE EVALUATION of OCULOMETRIC VARIABLES IN GRAVES' OPHTHALMOPATHY

dc.contributor.authorMiot, Hélio Amante [UNESP]
dc.contributor.authordos Santos Fernandes, Leonardo Parr
dc.contributor.authorJorge, Edson Nacib [UNESP]
dc.contributor.authorPivotto, Daniel Rosito [UNESP]
dc.contributor.authorNogueira, Célia Regina [UNESP]
dc.contributor.authorFerreira da Silva Mazeto, Glaucia Maria [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de Marília (UNIMAR)
dc.date.accessioned2014-05-20T13:34:08Z
dc.date.available2014-05-20T13:34:08Z
dc.date.issued2009-01-01
dc.description.abstractOBJECTIVES: To estimate oculometric parameters of Graves' ophthalmopathy in comparison to healthy eyes using digital photography and digital image analysis.INTRODUCTION: Graves' ophthalmopathy is the main cause of eye proptosis. Because these protrusions cause clinically perceived distortions in orbital architecture, digital photographs can be used to detect and quantify these changes.METHODS: We carried out a cross-sectional study comprising 12 healthy volunteers and 15 Graves' ophthalmopathy patients with the purpose of evaluating the use of simple, non-invasive digital photography to estimate oculometric parameters of Graves' ophthalmopathy and compare them with the parameters of unaffected eyes. Facial photographs of cases and controls were taken in a standardized manner. Oculometric parameters were compared between the groups and then correlated to proptometer measures.RESULTS: All estimated oculometric variables showed significant differences between the groups, in particular with regard to mediopupilar aperture, lateral height, distance from the iris edge to the lateral boundary of the palpebral fissure, and distance from the higher point of the iris to the lateral limit of the palpebral fissure. The product of medial aperture and horizontal palpebral fissure also revealed greater discrepancy between the groups. Proptometer measures showed significant linear correlation between the distance from the iris edge to the lateral boundary of the palpebral fissure and between the distance from the higher point of the iris to the lateral limit of palpebral fissure (p<0.05).CONCLUSIONS: Comparative analysis of oculometric parameters in Graves' ophthalmopathy suggests that eye proptosis is related to an asymmetric increase in lateral oculometric measures. Standardized digital photographs can be used in clinical practice to objectively estimate oculometric parameters of Graves' ophthalmopathy patients.en
dc.description.affiliationSão Paulo State Univ UNESP, Botucatu Med Sch, Dept Dermatol, Botucatu, SP, Brazil
dc.description.affiliationUniv Marilia, Dept Internal Med, Marilia, SP, Brazil
dc.description.affiliationSão Paulo State Univ UNESP, Botucatu Med Sch, Dept Ophthalmol, Botucatu, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Botucatu Med Sch, Dept Dermatol, Botucatu, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Botucatu Med Sch, Dept Ophthalmol, Botucatu, SP, Brazil
dc.format.extent885-889
dc.identifierhttp://dx.doi.org/10.1590/S1807-59322009000900009
dc.identifier.citationClinics. São Paulo: Hospital Clinicas, Univ São Paulo, v. 64, n. 9, p. 885-889, 2009.
dc.identifier.doi10.1590/S1807-59322009000900009
dc.identifier.fileS1807-59322009000900009.pdf
dc.identifier.issn1807-5932
dc.identifier.lattes2543633050941005
dc.identifier.lattes6692227903300380
dc.identifier.lattes0000-0003-3121-440X
dc.identifier.scieloS1807-59322009000900009
dc.identifier.urihttp://hdl.handle.net/11449/11693
dc.identifier.wosWOS:000270232700009
dc.language.isoeng
dc.publisherUniversidade de São Paulo (USP), Hospital das Clínicas
dc.relation.ispartofClinics
dc.relation.ispartofjcr1.245
dc.relation.ispartofsjr0,536
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectBiometryen
dc.subjectEye abnormalitiesen
dc.subjectGraves' diseaseen
dc.subjectGraves'en
dc.subjectOphthalmopathyen
dc.subjectPhotographyen
dc.titleCOMPARATIVE EVALUATION of OCULOMETRIC VARIABLES IN GRAVES' OPHTHALMOPATHYen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/clin/paboutj.htm
dcterms.rightsHolderHospital Clinicas, Univ São Paulo
dspace.entity.typePublication
unesp.author.lattes2543633050941005
unesp.author.lattes6692227903300380[3]
unesp.author.lattes7607038776901890[5]
unesp.author.orcid0000-0002-2596-9294[1]
unesp.author.orcid0000-0003-2129-7256[6]
unesp.author.orcid0000-0003-3121-440X[3]
unesp.author.orcid0000-0002-4014-0660[5]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.departmentDermatologia e Radioterapia - FMBpt
unesp.departmentOftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço - FMBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: