Two-year Clinical Performance of Self-etching Adhesive Systems in Composite Restorations of Anterior Teeth

dc.contributor.authorBarcellos, D. C. [UNESP]
dc.contributor.authorBatista, G. R. [UNESP]
dc.contributor.authorSilva, M. A. [UNESP]
dc.contributor.authorPleffken, P. R. [UNESP]
dc.contributor.authorRangel, P. M. [UNESP]
dc.contributor.authorFernandes, V. V. B. [UNESP]
dc.contributor.authorDi Nicolo, R. [UNESP]
dc.contributor.authorTorres, C. R. G. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:11:12Z
dc.date.available2014-12-03T13:11:12Z
dc.date.issued2013-05-01
dc.description.abstractObjective: The aim of this study was to evaluate the two-year clinical performance of Class III, IV, and V composite restorations using a two-step etch-and-rinse adhesive system (2-ERA) and three one-step self-etching adhesive systems (1-SEAs).Material and Methods: Two hundred Class III, IV, and V composite restorations were placed into 50 patients. Each patient received four composite restorations (Amaris, Voco), and these restorations were bonded with one of three 1-SEAs (Futurabond M, Voco; Clearfil S3 Bond, Kuraray; and Optibond All-in-One, Kerr) or one 2-ERA (Adper Single Bond 2/3M ESPE). The four adhesive systems were evaluated at baseline and after 24 months using the following criteria: restoration retention, marginal integrity, marginal discoloration, caries occurrence, postoperative sensitivity and preservation of tooth vitality. After two years, 162 restorations were evaluated in 41 patients. Data were analyzed using the chi(2) test (p<0.05).Results: There were no statistically significant differences between the 2-ERA and the 1-SEAs regarding the evaluated parameters (p>0.05).Conclusion: The 1-SEAs showed good clinical performance at the end of 24 months.en
dc.description.affiliationUNESP Univ Estadual Paulista, Sao Jose dos Campos Sch Dent, Sao Paulo, Brazil
dc.description.affiliationUNESP Sao Paulo State Univ, Dept Restorat Dent, Sao Jose dos Campos Dent Sch, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Sao Jose dos Campos Sch Dent, Sao Paulo, Brazil
dc.description.affiliationUnespUNESP Sao Paulo State Univ, Dept Restorat Dent, Sao Jose dos Campos Dent Sch, BR-12245000 Sao Jose Dos Campos, SP, Brazil
dc.format.extent258-266
dc.identifierhttp://dx.doi.org/10.2341/11-397-C
dc.identifier.citationOperative Dentistry. Indianapolis: Operative Dentistry Inc, v. 38, n. 3, p. 258-266, 2013.
dc.identifier.doi10.2341/11-397-C
dc.identifier.fileWOS000318825300004.pdf
dc.identifier.issn0361-7734
dc.identifier.lattes3135367849609938
dc.identifier.urihttp://hdl.handle.net/11449/112975
dc.identifier.wosWOS:000318825300004
dc.language.isoeng
dc.publisherOperative Dentistry Inc
dc.relation.ispartofOperative Dentistry
dc.relation.ispartofjcr2.130
dc.relation.ispartofsjr1,180
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.titleTwo-year Clinical Performance of Self-etching Adhesive Systems in Composite Restorations of Anterior Teethen
dc.typeArtigo
dcterms.rightsHolderOperative Dentistry Inc
unesp.author.lattes3135367849609938[8]
unesp.author.orcid0000-0002-9485-5514[8]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentOdontologia Restauradora - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000318825300004.pdf
Tamanho:
417.56 KB
Formato:
Adobe Portable Document Format