Fadiga de grampos de retenção em prótese parcial removível. Efeito de ligas, espessuras e técnicas de fusão. Parte I.

dc.contributor.authorMachado Cucci, A. L.
dc.contributor.authorFuller, J. B.
dc.contributor.authorGiampaolo, E. T.
dc.contributor.authorLeonardi, P.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:14:17Z
dc.date.available2014-05-27T11:14:17Z
dc.date.issued1990-12-01
dc.description.abstractThe authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.en
dc.format.extent245-250
dc.identifierhttp://www.revodontolunesp.com.br/articles/view/id/51ae4a9b1ef1faca3d0021b7
dc.identifier.citationRevista de Odontologia da UNESP, v. 19, n. 1, p. 245-250, 1990.
dc.identifier.file2-s2.0-0025561569.pdf
dc.identifier.issn0101-1774
dc.identifier.scopus2-s2.0-0025561569
dc.identifier.urihttp://hdl.handle.net/11449/64069
dc.language.isopor
dc.relation.ispartofRevista de Odontologia da UNESP
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectchromium derivative
dc.subjectdenture
dc.subjecthuman
dc.subjectmaterials testing
dc.subjectpremolar tooth
dc.subjectBicuspid
dc.subjectChromium Alloys
dc.subjectDental Casting Technique
dc.subjectDenture Retention
dc.subjectDenture, Partial, Removable
dc.subjectEnglish Abstract
dc.subjectHuman
dc.subjectMaterials Testing
dc.titleFadiga de grampos de retenção em prótese parcial removível. Efeito de ligas, espessuras e técnicas de fusão. Parte I.pt
dc.title.alternativeFatigue of retentive clasps of removable partial dentures. Effect of alloys, thickness and casting techniques. 1en
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/rounesp/paboutj.htm#03

Arquivos