Digital Image Correlation and Finite Element Analysis of Bone Strain Generated by Implant-Retained Cantilever Fixed Prosthesis
Carregando...
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Tipo
Artigo
Direito de acesso
Resumo
PURPOSE: The present study evaluated the displacement and strain generated in an implant- supported fixed prosthesis under axial and non-axial loads using two methods. MATERIALS AND METHODS: Three implants were inserted in a resin block. The Digital Image Correlation (DIC) was used to measure displacement and strain generated on the surface of the resin blocks for the different load applications (500N, 1 image/second). A 3-dimensional model was constructed and a load of 500 N was applied at an axial point and a non-axial point through finite element analysis (FEA). RESULTS: Both methods gave similar trends for the strains, and both gave slightly higher strains with non-axial loading. FEA predicted higher strain magnitude (±11%) in comparison with DIC, but with the same mechanical behavior. According to ANOVA, the loading influenced the strain concentration. Higher strain was generated for non-axial loading around the implant nearest to the loading. CONCLUSIONS: For implant-retained cantilever fixed prosthesis, the same load applied in the lever arm induces higher strain in the cervical area of the last implant, which suggests more damaging potential than a load applied at the center of the prosthesis.
Descrição
Palavras-chave
Biomechanical Complications, Computerized Models, Dental Implant, Finite Element Analysis
Idioma
Inglês
Citação
The European journal of prosthodontics and restorative dentistry, v. 28, n. 1, p. 10-17, 2020.