Simulations of the Frequency Modulated Atomic Force Microscope (FM-AFM) nonlinear control system
dc.contributor.author | Bueno, Atila Madureira [UNESP] | |
dc.contributor.author | Balthazar, José Manoel [UNESP] | |
dc.contributor.author | Piqueira, José Roberto Castilho | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Escola Politécnica da Universidade de São Paulo | |
dc.date.accessioned | 2016-03-02T12:58:12Z | |
dc.date.available | 2016-03-02T12:58:12Z | |
dc.date.issued | 2011 | |
dc.description.abstract | The Frequency Modulated - Atomic Force Microscope (FM-AFM) is apowerful tool to perform surface investigation with true atomic resolution. The controlsystem of the FM-AFM must keep constant both the frequency and amplitude ofoscillation of the microcantilever during the scanning process of the sample. However,tip and sample interaction forces cause modulations in the microcantilever motion.A Phase-Locked Loop (PLL) is used as a demodulator and to generate feedback signalto the FM-AFM control system. The PLL performance is vital to the FM-AFMperformace since the image information is in the modulated microcantilever motion.Nevertheless, little attention is drawn to PLL performance in the FM-AFM literature.Here, the FM-AFM control system is simulated, comparing the performancefor di erent PLL designs. | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Estatística, Matemática Aplicada e Computacional, Instituto de Geociências e Ciências Exatas de Rio Claro, Rio Claro, Avenida 24A. 1515., Bela Vista, CEP 13506-700, SP, Brasil | |
dc.description.affiliation | Escola Politécnica, Universidade de São Paulo, Av. Prof. Luciano Gualberto, travessa 3, n. 158, 05508-900, São Paulo, SP, Brazil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Estatística, Matemática Aplicada e Computacional, Instituto de Geociências e Ciências Exatas de Rio Claro, Rio Claro, Avenida 24A. 1515., Bela Vista, CEP 13506-700, SP, Brasil | |
dc.format.extent | 176-186 | |
dc.identifier | http://www.cmsim.eu/journal_issues.html | |
dc.identifier.citation | Journal of Chaotic Modeling and Simulation, v. 1, p. 176-186, 2011. | |
dc.identifier.issn | 2241-0503 | |
dc.identifier.lattes | 9728054402919622 | |
dc.identifier.lattes | 7416585768192991 | |
dc.identifier.lattes | 6644721827442957 | |
dc.identifier.uri | http://hdl.handle.net/11449/134743 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Chaotic Modeling and Simulation | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.subject | Frequency Modulated Atomic Force Microscope | en |
dc.subject | Phase-Locked Loops | en |
dc.subject | Synchronization | en |
dc.title | Simulations of the Frequency Modulated Atomic Force Microscope (FM-AFM) nonlinear control system | en |
dc.type | Artigo | |
unesp.author.lattes | 9728054402919622 | |
unesp.author.lattes | 7416585768192991[1] | |
unesp.author.lattes | 6644721827442957 | |
unesp.author.orcid | 0000-0002-1113-3330[1] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Geociências e Ciências Exatas, Rio Claro | pt |
unesp.department | Estatística, Matemática Aplicada e Computacional - IGCE | pt |