Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant
dc.contributor.author | Matos, Jefferson David Melo de [UNESP] | |
dc.contributor.author | Lopes, Guilherme da Rocha Scalzer [UNESP] | |
dc.contributor.author | Queiroz, Daher Antonio | |
dc.contributor.author | Pereira, André Luiz Jesus | |
dc.contributor.author | Sinhoreti, Mário Alexandre Coelho | |
dc.contributor.author | Ramos, Nathália de Carvalho [UNESP] | |
dc.contributor.author | Lino, Vinicius [UNESP] | |
dc.contributor.author | de Oliveira, Flavio Rosa [UNESP] | |
dc.contributor.author | Borges, Alexandre Luiz Souto [UNESP] | |
dc.contributor.author | Bottino, Marco Antonio [UNESP] | |
dc.contributor.institution | University of Florida (UF Health) | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | The University of Texas Health Science Center at Houston (UTHealth) | |
dc.contributor.institution | Aeronautics Technological Institute (ITA) | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.contributor.institution | Universidade São Francisco (USF) | |
dc.contributor.institution | University of Taubaté (UNITAU) | |
dc.date.accessioned | 2023-07-29T15:15:13Z | |
dc.date.available | 2023-07-29T15:15:13Z | |
dc.date.issued | 2022-11-01 | |
dc.description.abstract | The present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 × 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 × 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30°) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30°). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation. | en |
dc.description.affiliation | Department of Restorative Dental Sciences Center for Dental Biomaterials University of Florida (UF Health) | |
dc.description.affiliation | Department of Biomaterials Dental Materials and Prosthodontics São Paulo State University (Unesp) Institute of Science and Technology, SP | |
dc.description.affiliation | Department of Restorative Dentistry & Prosthodontics School of Dentistry The University of Texas Health Science Center at Houston (UTHealth) | |
dc.description.affiliation | Plasmas and Processes Laboratory Physics Departament Aeronautics Technological Institute (ITA), 50 Marechal Eduardo Gomes Square, SP | |
dc.description.affiliation | Department of Restorative Dentistry Dental Materials Division Piracicaba Dental School (FOP-UNICAMP), SP | |
dc.description.affiliation | Department of Dentistry Universidade São Francisco (USF), SP | |
dc.description.affiliation | Department of Dentistry Postgraduate Program in Dentistry University of Taubaté (UNITAU), SP | |
dc.description.affiliationUnesp | Department of Biomaterials Dental Materials and Prosthodontics São Paulo State University (Unesp) Institute of Science and Technology, SP | |
dc.identifier | http://dx.doi.org/10.3390/ma15228133 | |
dc.identifier.citation | Materials, v. 15, n. 22, 2022. | |
dc.identifier.doi | 10.3390/ma15228133 | |
dc.identifier.issn | 1996-1944 | |
dc.identifier.scopus | 2-s2.0-85142729490 | |
dc.identifier.uri | http://hdl.handle.net/11449/249408 | |
dc.language.iso | eng | |
dc.relation.ispartof | Materials | |
dc.source | Scopus | |
dc.subject | bioengineering | |
dc.subject | dental abutments | |
dc.subject | dental implants | |
dc.subject | dental materials | |
dc.subject | polyetheretherketone | |
dc.title | Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant | en |
dc.type | Artigo | |
unesp.author.orcid | 0000-0003-4507-0785[1] | |
unesp.author.orcid | 0000-0002-1477-8599[3] | |
unesp.author.orcid | 0000-0003-4757-8080[4] | |
unesp.author.orcid | 0000-0002-1932-2902[5] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |