Influence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implant

dc.contributor.authorMatos, Jefferson David Melo de [UNESP]
dc.contributor.authorLopes, Guilherme da Rocha Scalzer [UNESP]
dc.contributor.authorQueiroz, Daher Antonio
dc.contributor.authorPereira, André Luiz Jesus
dc.contributor.authorSinhoreti, Mário Alexandre Coelho
dc.contributor.authorRamos, Nathália de Carvalho [UNESP]
dc.contributor.authorLino, Vinicius [UNESP]
dc.contributor.authorde Oliveira, Flavio Rosa [UNESP]
dc.contributor.authorBorges, Alexandre Luiz Souto [UNESP]
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.institutionUniversity of Florida (UF Health)
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionThe University of Texas Health Science Center at Houston (UTHealth)
dc.contributor.institutionAeronautics Technological Institute (ITA)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade São Francisco (USF)
dc.contributor.institutionUniversity of Taubaté (UNITAU)
dc.date.accessioned2023-07-29T15:15:13Z
dc.date.available2023-07-29T15:15:13Z
dc.date.issued2022-11-01
dc.description.abstractThe present study aimed to evaluate the biomechanical behavior of PEEK abutments with different heights on single titanium implants. To investigate the implant surface, different tests (scanning electron microscopy, energy-dispersive X-ray, and X-ray diffraction) were adopted. Herein, 20 implants received the 4.5 × 4.0 mm PEEK short abutment (SA) and 20 received the 4.5 × 5.5 mm PEEK long abutment (LA). The abutments were installed using dual-cure resin cement. To determine the fatigue test, two specimens from each group were submitted to the single load fracture test. For this, the samples were submitted to a compressive load of (0.5 mm/min; 30°) in a universal testing machine. For the fatigue test, the samples received 2,000,000 cycles (2 Hz; 30°). The number of cycles and the load test was analyzed by the reliability software SPSS statistics using Kaplan-Meier and Mantel-Cox tests (log-rank) (p < 0.05). The maximum load showed no statistically significant differences (p = 0.189) for the SA group (64.1 kgf) and the LA group (56.5 kgf). The study groups were statistically different regarding the number of cycles (p = 0.022) and fracture strength (p = 0.001). PEEK abutments can be indicated with caution for implant-supported rehabilitation and may be suitable as temporary rehabilitation.en
dc.description.affiliationDepartment of Restorative Dental Sciences Center for Dental Biomaterials University of Florida (UF Health)
dc.description.affiliationDepartment of Biomaterials Dental Materials and Prosthodontics São Paulo State University (Unesp) Institute of Science and Technology, SP
dc.description.affiliationDepartment of Restorative Dentistry & Prosthodontics School of Dentistry The University of Texas Health Science Center at Houston (UTHealth)
dc.description.affiliationPlasmas and Processes Laboratory Physics Departament Aeronautics Technological Institute (ITA), 50 Marechal Eduardo Gomes Square, SP
dc.description.affiliationDepartment of Restorative Dentistry Dental Materials Division Piracicaba Dental School (FOP-UNICAMP), SP
dc.description.affiliationDepartment of Dentistry Universidade São Francisco (USF), SP
dc.description.affiliationDepartment of Dentistry Postgraduate Program in Dentistry University of Taubaté (UNITAU), SP
dc.description.affiliationUnespDepartment of Biomaterials Dental Materials and Prosthodontics São Paulo State University (Unesp) Institute of Science and Technology, SP
dc.identifierhttp://dx.doi.org/10.3390/ma15228133
dc.identifier.citationMaterials, v. 15, n. 22, 2022.
dc.identifier.doi10.3390/ma15228133
dc.identifier.issn1996-1944
dc.identifier.scopus2-s2.0-85142729490
dc.identifier.urihttp://hdl.handle.net/11449/249408
dc.language.isoeng
dc.relation.ispartofMaterials
dc.sourceScopus
dc.subjectbioengineering
dc.subjectdental abutments
dc.subjectdental implants
dc.subjectdental materials
dc.subjectpolyetheretherketone
dc.titleInfluence of the Peek Abutments on Mechanical Behavior of the Internal Connections Single Implanten
dc.typeArtigo