Publicação: A steep peripheral ring in irregular cornea topography, real or an instrument error?
dc.contributor.author | Galindo-Ferreiro, Alicia | |
dc.contributor.author | Galvez-Ruiz, Alberto | |
dc.contributor.author | Schellini, Silvana A. [UNESP] | |
dc.contributor.author | Galindo-Alonso, Julio | |
dc.contributor.institution | King Khaled Eye Specialist Hospital | |
dc.contributor.institution | Complejo Asistencial Palencia | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Galindo Clinic | |
dc.contributor.institution | Rio Hortega University Hospital | |
dc.date.accessioned | 2018-12-11T17:07:24Z | |
dc.date.available | 2018-12-11T17:07:24Z | |
dc.date.issued | 2016-07-01 | |
dc.description.abstract | Purpose To demonstrate that the steep peripheral ring (red zone) on corneal topography after myopic laser in situ keratomileusis (LASIK) could possibly due to instrument error and not always to a real increase in corneal curvature. Methods A spherical model for the corneal surface and modifying topography software was used to analyze the cause of an error due to instrument design. This study involved modification of the software of a commercially available topographer. Results A small modification of the topography image results in a red zone on the corneal topography color map. Conclusion Corneal modeling indicates that the red zone could be an artifact due to an instrument-induced error. The steep curvature changes after LASIK, signified by the red zone, could be also an error due to the plotting algorithms of the corneal topographer, besides a steep curvature change. | en |
dc.description.affiliation | King Khaled Eye Specialist Hospital, Al Urubah Branch Rd, Umm Al Hamam Al Gharbi | |
dc.description.affiliation | Department of Ophthalmology Complejo Asistencial Palencia, Donantes de sangre s/n | |
dc.description.affiliation | Department of Ophthalmology Faculdade de Medicina de Botucatu – UNESP | |
dc.description.affiliation | Galindo Clinic, Francisco Zarandona St 10 | |
dc.description.affiliation | Rio Hortega University Hospital, Dulzaina St 2 | |
dc.description.affiliationUnesp | Department of Ophthalmology Faculdade de Medicina de Botucatu – UNESP | |
dc.format.extent | 175-179 | |
dc.identifier | http://dx.doi.org/10.1016/j.sjopt.2016.04.002 | |
dc.identifier.citation | Saudi Journal of Ophthalmology, v. 30, n. 3, p. 175-179, 2016. | |
dc.identifier.doi | 10.1016/j.sjopt.2016.04.002 | |
dc.identifier.file | 2-s2.0-84993984951.pdf | |
dc.identifier.issn | 1319-4534 | |
dc.identifier.scopus | 2-s2.0-84993984951 | |
dc.identifier.uri | http://hdl.handle.net/11449/173711 | |
dc.language.iso | eng | |
dc.relation.ispartof | Saudi Journal of Ophthalmology | |
dc.relation.ispartofsjr | 0,451 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | Irregular corneal astigmatism | |
dc.subject | Red zone | |
dc.subject | Spherical aberration | |
dc.subject | Topography | |
dc.title | A steep peripheral ring in irregular cornea topography, real or an instrument error? | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatu | pt |
unesp.department | Oftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço - FMB | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-84993984951.pdf
- Tamanho:
- 855.52 KB
- Formato:
- Adobe Portable Document Format
- Descrição: