Publicação:
Acoustic and psychoacoustic analysis of the noise produced by the police force firearms

dc.contributor.authorGuida, Heraldo Lorena [UNESP]
dc.contributor.authorDiniz, Thiago Hernandes [UNESP]
dc.contributor.authorKinoshita, Sergio Koodi [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:31:34Z
dc.date.available2014-05-20T13:31:34Z
dc.date.issued2011-03-01
dc.description.abstractPolice officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.en
dc.description.abstractOs policiais militares estão expostos a ruídos de impacto provenientes de armas de fogo, os quais são capazes de causar lesões irreversíveis ao sistema auditivo. OBJETIVO: Avaliar a exposição ao ruído no estande de tiros durante os exercícios de tiro, analisar acusticamente o ruído de impacto e relacioná-lo com os resultados de audiometria tonal. FORMA DE ESTUDO: Transversal. MATERIAL E MÉTODO: A medição do ruído foi feita por meio de decibelímetro digital e a análise acústica foi feita no software Praat, levantando as curvas de oscilograma e cocleograma. Foi selecionada uma amostra de 30 policiais militares (27 masculinos e 3 femininos). RESULTADOS: Os picos máximos medidos no estante de tiros foram de 113,1 dB(C) para pistola .40 e 116,8 dB(C) para revólver .38. Os valores obtidos por meio da relação entre o oscilograma temporal e cocleograma Praat ficaram entre 17,9±0,3 Barks, correspondendo à faixa entre 4120 e 4580 Hz. As medidas da audiometria indicaram maior perda auditiva na faixa de 4000Hz em 86,7% dos casos. CONCLUSÃO: A partir da análise acústica dos tiros, foi possível demonstrar causa e efeito entre as principais áreas de excitação de energia na cóclea (cocleograma Praat) e as frequências com diminuição de acuidade auditiva.pt
dc.description.affiliationUniv Estadual Paulista, Fac Filosofia & Ciencias, BR-17525900 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fac Filosofia & Ciencias, BR-17525900 São Paulo, Brazil
dc.format.extent163-170
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S1808-86942011000200005&lng=pt&nrm=iso&tlng=pt
dc.identifier.citationBrazilian Journal of Otorhinolaryngology. São Paulo: Assoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial, v. 77, n. 2, p. 163-170, 2011.
dc.identifier.fileS1808-86942011000200005-pt.pdf
dc.identifier.fileS1808-86942011000200005-en.pdf
dc.identifier.issn1808-8694
dc.identifier.lattes2545336847709120
dc.identifier.scieloS1808-86942011000200005
dc.identifier.urihttp://hdl.handle.net/11449/10755
dc.identifier.wosWOS:000293578500005
dc.language.isoeng
dc.publisherAssoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial
dc.relation.ispartofBrazilian Journal of Otorhinolaryngology
dc.relation.ispartofjcr1.412
dc.relation.ispartofsjr0,443
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectfirearmsen
dc.subjectpoliceen
dc.subjectnoiseen
dc.subjectoccupationalen
dc.titleAcoustic and psychoacoustic analysis of the noise produced by the police force firearmsen
dc.title.alternativeAnálise acústica e psicoacústica do ruído de armas utilizadas pela Polícia Militarpt
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/bjorl/paboutj.htm
dcterms.rightsHolderAssoc Brasileira Otorrinolaringologia & Cirurgia Cervicofacial
dspace.entity.typePublication
unesp.author.lattes2545336847709120
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Filosofia e Ciências, Maríliapt
unesp.departmentFonoaudiologia - FFCpt

Arquivos

Pacote Original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
S1808-86942011000200005-en.pdf
Tamanho:
345.19 KB
Formato:
Adobe Portable Document Format
Descrição:
Carregando...
Imagem de Miniatura
Nome:
S1808-86942011000200005-pt.pdf
Tamanho:
366.2 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: