Optimization of an amperometric biosensor for the detection of hepatitis C virus using fractional factorial designs
dc.contributor.author | Uliana, Carolina V. [UNESP] | |
dc.contributor.author | Riccardi, Carla S. [UNESP] | |
dc.contributor.author | Tognolli, Joao O. [UNESP] | |
dc.contributor.author | Yamanaka, Hideko [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:19:21Z | |
dc.date.available | 2014-05-20T14:19:21Z | |
dc.date.issued | 2008-01-01 | |
dc.description.abstract | Fractional factorial design and factorial with center point design were applied to the development of an amperometric biosensor for the detection of the hepatitis C virus. Biomolecules were immobilized by adsorption on graphite electrodes modified with siloxane-poly(propyleneoxide) hybrid matrix prepared using the sol-gel method. Several parameters were optimized, such as the streptavidin concentration at 0.01 mg mL(-1) and 1.0% bovine serum albumin, the incubation time of the electrodes in the complementary DNA solution for 30 minutes and a 1: 1500 dilution of the avidin-peroxidase conjugate, among others. The application of chemometric studies has been efficient, since the best conditions have been established with a restricted number of experiments, indicating the influence of different factors on the system. | en |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, BR-14800900 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, BR-14800900 Araraquara, SP, Brazil | |
dc.format.extent | 782-787 | |
dc.identifier | http://dx.doi.org/10.1590/S0103-50532008000400024 | |
dc.identifier.citation | Journal of The Brazilian Chemical Society. São Paulo: Soc Brasileira Quimica, v. 19, n. 4, p. 782-787, 2008. | |
dc.identifier.doi | 10.1590/S0103-50532008000400024 | |
dc.identifier.file | S0103-50532008000400024.pdf | |
dc.identifier.issn | 0103-5053 | |
dc.identifier.lattes | 1923726000036625 | |
dc.identifier.scielo | S0103-50532008000400024 | |
dc.identifier.uri | http://hdl.handle.net/11449/25839 | |
dc.identifier.wos | WOS:000256957100023 | |
dc.language.iso | eng | |
dc.publisher | Soc Brasileira Quimica | |
dc.relation.ispartof | Journal of the Brazilian Chemical Society | |
dc.relation.ispartofjcr | 1.444 | |
dc.relation.ispartofsjr | 0,357 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | biosensor | en |
dc.subject | hepatitis C virus | en |
dc.subject | fractional factorial design | en |
dc.title | Optimization of an amperometric biosensor for the detection of hepatitis C virus using fractional factorial designs | en |
dc.type | Artigo | |
dcterms.rightsHolder | Soc Brasileira Quimica | |
unesp.author.lattes | 1923726000036625 | |
unesp.author.lattes | 0173401604473200[2] | |
unesp.author.orcid | 0000-0003-2192-5312[2] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: