Transient Responses on Transmission Lines Located above Frequency-Dependent Soil with Variable Water Content

dc.contributor.authorPascoalato, Taina F. G. [UNESP]
dc.contributor.authorDe Araujo, Anderson R. J.
dc.contributor.authorKurokawa, Sergio [UNESP]
dc.contributor.authorFilho, Jose Pissolato
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2022-05-01T12:56:30Z
dc.date.available2022-05-01T12:56:30Z
dc.date.issued2021-01-01
dc.description.abstractThis paper investigates the influence of frequency-dependent soil parameters with variable water content in the transient responses of single-circuit three-phase transmission line (TL) subjected to lightning subsequent return stroke. For this purpose, we use the Nakagawa's approach to compute the ground-return impedance and admittance matrices the frequency-dependent soil modeled by Messier is employed. With the Nakagawa's approach, four water contents of 0.90%, 2.57%, 4.04% and 11.57% are selected with results in low-frequency resistivity of 5000, 1000, 500 and 100 Ω.m. The transient responses for single-circuit three-phase line located above soils of 100, 500, 1000, and 5000 Ω.m considering the frequency-constant soil using the Carson's approach are compare. Results demonstrated that the inclusion of frequency dependence of soil leads to an expressive reduction of approximately 19.52% and 60.16% in the generated voltage peaks (first and third) for this TL located above a high-resistive soil of 5000 Ω.m and lower water content W = 0.90%. This work shows the impact of the frequency-dependent soil that must be taken into account for adequate transient in power systems.en
dc.description.affiliationSão Paulo State University (UNESP) Department of Electrical Engineering
dc.description.affiliationState University of Campinas (UNICAMP) School of Electrical and Computer Engineering
dc.description.affiliationUnespSão Paulo State University (UNESP) Department of Electrical Engineering
dc.identifierhttp://dx.doi.org/10.1109/WCNPS53648.2021.9626280
dc.identifier.citation2021 Workshop on Communication Networks and Power Systems, WCNPS 2021.
dc.identifier.doi10.1109/WCNPS53648.2021.9626280
dc.identifier.scopus2-s2.0-85123489587
dc.identifier.urihttp://hdl.handle.net/11449/234051
dc.language.isoeng
dc.relation.ispartof2021 Workshop on Communication Networks and Power Systems, WCNPS 2021
dc.sourceScopus
dc.subjectfrequency-dependent soils
dc.subjectlightning
dc.subjecttransient analysis
dc.subjecttransmission lines
dc.subjectwater content
dc.titleTransient Responses on Transmission Lines Located above Frequency-Dependent Soil with Variable Water Contenten