Publicação:
Influence of Different Ceramics on Resin Cement Knoop Hardness Number

dc.contributor.authorBorges, G. A.
dc.contributor.authorAgarwal, P.
dc.contributor.authorMiranzi, B. A. S.
dc.contributor.authorPlatt, J. A.
dc.contributor.authorValentino, T. A.
dc.contributor.authorSantos, Paulo Henrique dos [UNESP]
dc.contributor.institutionUniv Uberaba
dc.contributor.institutionIndiana University
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:10Z
dc.date.accessioned2014-05-20T13:43:46Z
dc.date.available2013-09-30T18:30:10Z
dc.date.available2014-05-20T13:43:46Z
dc.date.issued2008-11-01
dc.description.abstractThis study evaluated: 1) the effect of different ceramics on light attenuation that could affect microhardness, measured as the Knoop Hardness Number (KHN), of a resin cement immediately and 24 hours after polymerization and 2) the effect of different activation modes (direct light-activation, light activation through ceramics and chemical activation) on the KHN of a resin cement.Resin cement Rely X ARC (3M ESPE) specimens 5.0 mm in diameter and 1.0 nun thick were made in a Teflon mold covered with a polyester film. The cement was directly light activated for 40 seconds with an XL 2500 curing unit (3M ESPE) with 650 mW/cm(2), light activated through ceramic discs of Duceram Plus (DeguDent), Cergogold (DeguDent), IPS Empress (Ivoclar), IPS Empress 2 (Ivoclar), Procera. (NobelBiocare), In Ceram Alumina (Vita) and Cercon (DeguDent), having a 1.2 mm thickness or chemically activated without light application. The resin cement specimens were flattened, and KHN was obtained using an HMV 2 microhardness tester (Shimadzu) with a load of 50 g applied for 15 seconds 100 pin from the irradiated surface immediately and after storage at 37 degrees C for 24 hours. Ten measurements were made for each specimen, with three specimens for each group at each time. The data were submitted to ANOVA and Tukey's test (p=0.05). The KHN of the resin cement was not only affected by the mode of activation, but also by the post-activation testing time. The mean KHN of the resin cement for chemical activation and through all ceramics showed statistically significant lower values compared to direct activation immediately and at 24 hours. The KHN for 24 hours post-activation was always superior to the immediate post-activation test except with direct activation. The most opaque ceramics resulted in the lowest KHN values.en
dc.description.affiliationUniv Uberaba, Dept Dent Mat & Restorat Dent, Uberaba, MG, Brazil
dc.description.affiliationIndiana Univ, Sch Dent, Div Prosthodont, Dept Restorat Dent, Indianapolis, IN USA
dc.description.affiliationUniv Uberaba, Dept Restorat Dent, Uberaba, MG, Brazil
dc.description.affiliationUniv Estadual Campinas, Fac Dent Piracicaba, Dept Restorat Dent, Piracicaba, SP, Brazil
dc.description.affiliationUniv Estadual Paulista, Fac Dent Aracatuba, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Fac Dent Aracatuba, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.format.extent622-628
dc.identifierhttp://dx.doi.org/10.2341/07-155
dc.identifier.citationOperative Dentistry. Indianapolis: Operative Dentistry Inc, v. 33, n. 6, p. 622-628, 2008.
dc.identifier.doi10.2341/07-155
dc.identifier.issn0361-7734
dc.identifier.lattes0493479801083622
dc.identifier.orcid0000-0002-4100-5153
dc.identifier.urihttp://hdl.handle.net/11449/15296
dc.identifier.wosWOS:000261034900006
dc.language.isoeng
dc.publisherOperative Dentistry Inc
dc.relation.ispartofOperative Dentistry
dc.relation.ispartofjcr2.130
dc.relation.ispartofsjr1,180
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleInfluence of Different Ceramics on Resin Cement Knoop Hardness Numberen
dc.typeArtigo
dcterms.rightsHolderOperative Dentistry Inc
dspace.entity.typePublication
unesp.author.lattes0493479801083622[6]
unesp.author.orcid0000-0002-4100-5153[6]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: