Publicação: Study of the electrical Power quality in the common connection point between a 7.8 kWp PV system and a low-voltage network
dc.contributor.author | Valverde-Granja, Agustin | |
dc.contributor.author | Souza, Teofilo M. de [UNESP] | |
dc.contributor.author | Magalhaes-Sobrinho, Pedro [UNESP] | |
dc.contributor.institution | Univ Ibague | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-11-26T16:04:28Z | |
dc.date.available | 2018-11-26T16:04:28Z | |
dc.date.issued | 2018-01-01 | |
dc.description.abstract | An experimental 1,000 kWh/month PV solar system was connected to a low-voltage network at the Universidad de Ibague, Colombia. In this work, we present the findings about the electrical voltage issues in the common connection point. The characterization of the low-voltage network was based on the NTC 5001standard, including aspects such as voltage imbalance, intermittency, short and long-term flicker, and harmonics. The maximum energy production was 850 kWh /month, equal to the 72.65% of the total installed capacity. In this condition, the minimum voltage measurements evidenced a 2 % increase from the previous value, the voltage imbalance was 3.5 to 70 percent lower, and the voltage harmonics (TDH) increased 7, 0.8 and 3 percent in the phases U-1, U-2 and U-3, respectively. Current harmonics did not show significant increases in lines U-2 and U-3, line U-1 recorded an increase of 22%, but there were no significant variations in the short and long-term flicker, notches and interruptions. Regarding the electrical power, the active and reactive components increased 58 and 42%, respectively, and the thermographic study indicated a 7.5 percent increasing temperature after the installation of the experimental PV system. This experience aims to be a reference project in the implementation of the Act 1715 of the Colombian government to promote solar | en |
dc.description.affiliation | Univ Ibague, Fac Engn, Ibague, Colombia | |
dc.description.affiliation | Univ Estadual Paulista UNESP, Fac Engn, Sao Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, Fac Engn, Sao Paulo, Brazil | |
dc.format.extent | 63-73 | |
dc.identifier | http://dx.doi.org/10.25100/iyc.v20i1.4222 | |
dc.identifier.citation | Ingenieria Y Competitividad. Cali: Univ Valle, Fac Ingenieria, v. 20, n. 1, p. 63-73, 2018. | |
dc.identifier.doi | 10.25100/iyc.v20i1.4222 | |
dc.identifier.issn | 0123-3033 | |
dc.identifier.uri | http://hdl.handle.net/11449/160436 | |
dc.identifier.wos | WOS:000438794200006 | |
dc.language.iso | eng | |
dc.publisher | Univ Valle, Fac Ingenieria | |
dc.relation.ispartof | Ingenieria Y Competitividad | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Low voltage network | |
dc.subject | Power quality | |
dc.subject | solar PV system | |
dc.subject | experimental network | |
dc.title | Study of the electrical Power quality in the common connection point between a 7.8 kWp PV system and a low-voltage network | en |
dc.type | Artigo | |
dcterms.rightsHolder | Univ Valle, Fac Ingenieria | |
dspace.entity.type | Publication |