Publicação: Sensitivity analysis of particle size distribution function during flocculation
Carregando...
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Assoc Brasileira Engenharia Sanitaria Ambiental
Tipo
Artigo
Direito de acesso
Acesso aberto

Resumo
In this paper, the sensitivity of the continuous particle size distribution function (PSD) was evaluated, as flocculation occurs. To this end, six discrete configurations were investigated, subdivided into 3, 4, 5, 6, 7, 8, 10 and 15 classes. The distribution studied here differ in the particles presented by size range and behavior, whether monotonic or unimodal. The adjustment of the continuous function in linearized form to the discrete data was evaluated by means of R-2. The power law coefficient (beta) and the center of mass (C.M) were taken as representative of PSD during the sensitivity analysis, which was carried out by means of multiple correlation between the variables. Batch essays were performed in order to evaluate simulations. Results showed that beta and C.M were both sensitive to PSD variations; however, the function adjustments for unimodal distributions need improvement.
Descrição
Palavras-chave
flocculation, particle size distribution, sensitivity analysis
Idioma
Português
Como citar
Engenharia Sanitaria E Ambiental. Rio De Janeiro: Assoc Brasileira Engenharia Sanitaria Ambiental, v. 25, n. 1, p. 1-9, 2020.