Publicação: Training on synthetic ethylene-vinyl acetate bench model allows novice medical students to acquire suture skills
dc.contributor.author | Denadai, Rafael | |
dc.contributor.author | Saad-Hossne, Rogerio [UNESP] | |
dc.contributor.author | Oshiiwa, Marie | |
dc.contributor.author | Bastos, Erika Malheiros | |
dc.contributor.institution | Universidade de Marília (UNIMAR) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T13:32:40Z | |
dc.date.available | 2014-05-20T13:32:40Z | |
dc.date.issued | 2012-03-01 | |
dc.description.abstract | PURPOSE: To assess the acquisition of suture skills by training on ethylene-vinyl acetate bench model in novice medical students.METHODS: Sixteen medical students without previous surgery experience (novices) were randomly divided into two groups. During one hour group A trained sutures on ethylene-vinyl acetate (EVA) bench model with feedback of instructors, while group B (control) received a faculty-directed training based on books and instructional videos. All students underwent a both pre-and post-tests to perform two-and three-dimensional sutures on ox tongue. All recorded performances were evaluated by two blinded evaluators, using the Global Rating Scale.RESULTS: Although both groups have had a better performance (p<0.05) in the post-test when compared with the pre-test, the analysis of post-test showed that group A (EVA) had a better performance (p<0.05) when compared with group B (control).CONCLUSION: The ethylene vinyl acetate bench model allowed the novice students to acquire suture skills faster when compared to the traditional model of teaching. | en |
dc.description.abstract | OBJETIVO: Avaliar a aquisição das habilidades de sutura com o treinamento no modelo de bancada de etileno vinil acetato em acadêmicos de medicina. MÉTODOS: Dezesseis estudantes de medicina iniciantes na prática cirúrgica foram divididos aleatoriamente em dois grupos. Durante uma hora o grupo A treinou diferentes suturas no modelo de bancada de etileno vinil acetato (EVA) com feedback dos instrutores, enquanto os do grupo B (controle) receberam um treinamento dirigido por instrutor baseado em livros e vídeos didáticos. Todos foram submetidos à pré e pós-testes para realização de suturas bi e tridimensionais em língua de boi. As performances gravadas foram avaliadas por dois avaliadores cegos, utilizando a Global Rating Scale. RESULTADOS: Embora os dois grupos tenham apresentado um melhor desempenho (p<0.05) no pós-teste quando comparado com o pré-teste, a análise do pós-teste mostrou que os alunos do grupo A (EVA) tiveram um melhor desempenho (p<0.05) quando comparados com os do grupo B (controle). CONCLUSÃO: O modelo de etileno vinil acetato permitiu que os alunos adquirissem habilidades de sutura mais rapidamente quando comparado ao modelo tradicional de ensino. | pt |
dc.description.affiliation | Univ Marilia, Div Plast & Reconstruct Surg, Dept Surg, Sch Med Sci, Marilia, SP, Brazil | |
dc.description.affiliation | São Paulo State Univ UNESP, Div Coloproctol, Dept Surg, Botucatu Med Sch, Botucatu, SP, Brazil | |
dc.description.affiliation | Fac Technol FATEC, Dept Stat, Botucatu, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Div Coloproctol, Dept Surg, Botucatu Med Sch, Botucatu, SP, Brazil | |
dc.format.extent | 271-278 | |
dc.identifier | http://dx.doi.org/10.1590/S0102-86502012000300012 | |
dc.identifier.citation | Acta Cirúrgica Brasileira. São Paulo: Acta Cirúrgica Brasileira, v. 27, n. 3, p. 271-278, 2012. | |
dc.identifier.file | S0102-86502012000300012-en.pdf | |
dc.identifier.issn | 0102-8650 | |
dc.identifier.scielo | S0102-86502012000300012 | |
dc.identifier.uri | http://hdl.handle.net/11449/11152 | |
dc.identifier.wos | WOS:000302080800012 | |
dc.language.iso | eng | |
dc.publisher | Acta Cirúrgica Brasileira | |
dc.relation.ispartof | Acta Cirúrgica Brasileira | |
dc.relation.ispartofjcr | 0.933 | |
dc.relation.ispartofsjr | 0,395 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Education, Medical | en |
dc.subject | Surgery | en |
dc.subject | Sutures | en |
dc.subject | Teaching | en |
dc.subject | Teaching Materials | en |
dc.title | Training on synthetic ethylene-vinyl acetate bench model allows novice medical students to acquire suture skills | en |
dc.title.alternative | Treinamento no modelo de bancada sintético de etileno vinil acetato permite que estudantes de medicina iniciantes na prática cirúrgica adquiram habilidades de sutura | pt |
dc.type | Artigo | |
dcterms.rightsHolder | Acta Cirúrgica Brasileira | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0003-0525-3480[1] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatu | pt |
unesp.department | Cirurgia e Ortopedia - FMB | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S0102-86502012000300012-en.pdf
- Tamanho:
- 447.33 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: