Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Reproducibility of 6-minute walking test in patients with COPD

dc.contributor.authorHernandes, N. A.
dc.contributor.authorWouters, E. F. M.
dc.contributor.authorMeijer, K.
dc.contributor.authorAnnegarn, J.
dc.contributor.authorPitta, F. [UNESP]
dc.contributor.authorSpruit, M. A.
dc.contributor.institutionMaastricht Univ
dc.contributor.institutionUniversidade Estadual de Londrina (UEL)
dc.contributor.institutionUniv Norte Parana UNOPAR
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:23:18Z
dc.date.available2014-05-20T13:23:18Z
dc.date.issued2011-08-01
dc.description.abstractThe reproducibility of the 6-min walking test (6MWT) needs to be more solidly studied. This study aimed to investigate the reproducibility of two 6MWTs performed on subsequent days in a large and representative sample of patients with chronic obstructive pulmonary disease (COPD), and to quantify the learning effect between the two tests, as well as its determinants.In a retrospective observational study, 1,514 patients with COPD performed two 6MWTs on subsequent days. Other measurements included body composition (dual X-ray absorptiometry), dyspnoea (Medical Research Council scale) and comorbidity (Charlson index).Although the 6MWT was reproducible (intraclass correlation coefficient=0.93), patients walked farther in the second test (391 m, 95% CI 155-585 m versus 418 m, 95% CI 185-605 m; p < 0.0001). on average, the second 6MWT increased by 27 m (or 7%), and 82% of patients improved in the second test. Determinants of improvement >= 42 m in the second test (upper limit of the clinically important change) were as follows: first 6MWT < 350 m, Charlson index < 2 and body mass index < 30 kg.m(-2) (OR 2.49, 0.76 and 0.60, respectively).The 6MWT was statistically reproducible in a representative sample of patients with COPD. However, the vast majority of patients improved significantly in the second test by an average learning effect of 27 m.en
dc.description.affiliationMaastricht Univ, Ctr Excellence Chron Organ Failure CIRO Horn, Program Dev Ctr, Maastricht, Netherlands
dc.description.affiliationMaastricht Univ, Maastricht Univ Med Ctr, Dept Resp Med, Maastricht, Netherlands
dc.description.affiliationMaastricht Univ, Fac Hlth Med & Life Sci, Dept Human Movement Sci, Maastricht, Netherlands
dc.description.affiliationUniversidade Estadual de Londrina (UEL), Lab Res Resp Physiotherapy LFIP, Dept Physiotherapy, Londrina, Brazil
dc.description.affiliationUniv Norte Parana UNOPAR, Londrina, Brazil
dc.description.affiliationUniv Estadual Paulista UNESP, Dept Physiotherapy, Postgrad Program Physiotherapy, Presidente Prudente, Brazil
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Dept Physiotherapy, Postgrad Program Physiotherapy, Presidente Prudente, Brazil
dc.description.sponsorshipEuropean Respiratory Society
dc.description.sponsorshipIdEuropean Respiratory Society: 634
dc.format.extent261-267
dc.identifierhttp://dx.doi.org/10.1183/09031936.00142010
dc.identifier.citationEuropean Respiratory Journal. Sheffield: European Respiratory Soc Journals Ltd, v. 38, n. 2, p. 261-267, 2011.
dc.identifier.doi10.1183/09031936.00142010
dc.identifier.issn0903-1936
dc.identifier.urihttp://hdl.handle.net/11449/7012
dc.identifier.wosWOS:000293280400008
dc.language.isoeng
dc.publisherEuropean Respiratory Soc Journals Ltd
dc.relation.ispartofEuropean Respiratory Journal
dc.relation.ispartofjcr12.242
dc.relation.ispartofsjr3,788
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectChronic obstructive pulmonary diseaseen
dc.subject6-min walking testen
dc.subjectreproducibility of resultsen
dc.titleReproducibility of 6-minute walking test in patients with COPDen
dc.typeArtigo
dcterms.licensehttp://erj.ersjournals.com/site/misc/ifora.xhtml
dcterms.rightsHolderEuropean Respiratory Soc Journals Ltd
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Ciências e Tecnologia, Presidente Prudentept
unesp.departmentFisioterapia - FCTpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: