Publicação:
Comparison of GEANT4 simulations with experimental data for thick al absorbers

dc.contributor.authorYevseyeva, Olga
dc.contributor.authorDe Assis, Joaquim
dc.contributor.authorEvseev, Ivan
dc.contributor.authorSchelin, Hugo
dc.contributor.authorPaschuk, Sergei
dc.contributor.authorMilhoretto, Edney
dc.contributor.authorSetti, João
dc.contributor.authorDíaz, Katherin
dc.contributor.authorHormaza, Joel [UNESP]
dc.contributor.authorLopes, Ricardo
dc.contributor.institutionUniversidade do Estado do Rio de Janeiro (UERJ)
dc.contributor.institutionUniversidade Tecnológica Federal do Paraná - UTFPR
dc.contributor.institutionCentro de Aplicaciones Tecnologicas y Desarrollo Nuclear - CEADEN
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal do Rio de Janeiro (UFRJ)
dc.date.accessioned2014-05-27T11:24:02Z
dc.date.available2014-05-27T11:24:02Z
dc.date.issued2009-11-27
dc.description.abstractProton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models provided by GEANT4 can lead to significant disagreements in the final proton energy spectra when integrated along lengthy proton trajectories. This work presents proton energy spectra obtained by GEANT4.8.2 simulations using ICRU49, Ziegler1985 and Ziegler2000 models for 19.68MeV protons passing through a number of Al absorbers with various thicknesses. The spectra were compared with the experimental data, with TRIM/SRIM2008 and MCNPX2.4.0 simulations, and with the Payne analytical solution for the transport equation in the Fokker-Plank approximation. It is shown that the MCNPX simulations reasonably reproduce well all experimental spectra. For the relatively thin targets all the methods give practically identical results but this is not the same for the thick absorbers. It should be noted that all the spectra were measured at the proton energies significantly above 2MeV, i.e., in the so-called Bethe-Bloch region. Therefore the observed disagreements in GEANT4 results, simulated with different models, are somewhat unexpected. Further studies are necessary for better understanding and definitive conclusions. © 2009 American Institute of Physics.en
dc.description.affiliationInstituto Politécnico da UERJ, Rua Alberto Rangel s/n, 28630-050, Nova Friburgo - RJ
dc.description.affiliationUniversidade Tecnológica Federal do Paraná - UTFPR, Av. Sete de Setembro 3166, 80230-901, Curitiba - PR
dc.description.affiliationCentro de Aplicaciones Tecnologicas y Desarrollo Nuclear - CEADEN, Calle 30 #502 e/5ta y 7ma Avenida, Playa, Ciudad Habana
dc.description.affiliationInstituto de Biociências da UNESP, Distrito de Rubião Jr. s/n, 18618-000, Botucatu - SP
dc.description.affiliationLaboratório de Instrumentação Nuclear COPPE/UFRJ, Av. Horácio Macedo 2030, 21941-914, Rio de Janeiro - RJ
dc.description.affiliationUnespInstituto de Biociências da UNESP, Distrito de Rubião Jr. s/n, 18618-000, Botucatu - SP
dc.format.extent97-101
dc.identifierhttp://dx.doi.org/10.1063/1.3157836
dc.identifier.citationAIP Conference Proceedings, v. 1139, p. 97-101.
dc.identifier.doi10.1063/1.3157836
dc.identifier.file2-s2.0-70450210220.pdf
dc.identifier.issn0094-243X
dc.identifier.issn1551-7616
dc.identifier.scopus2-s2.0-70450210220
dc.identifier.urihttp://hdl.handle.net/11449/71255
dc.language.isoeng
dc.relation.ispartofAIP Conference Proceedings
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectEnergy measurement
dc.subjectMonte carlo methods
dc.subjectProton beams
dc.titleComparison of GEANT4 simulations with experimental data for thick al absorbersen
dc.typeTrabalho apresentado em evento
dcterms.licensehttp://publishing.aip.org/authors/web-posting-guidelines
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatupt
unesp.departmentFísica e Biofísica - IBBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-70450210220.pdf
Tamanho:
643.44 KB
Formato:
Adobe Portable Document Format