Publicação:
Pulmonary decontamination for photodynamic inactivation with extracorporeal illumination

dc.contributor.authorGeralde, Mariana Carreira
dc.contributor.authorLeite, Ilaiali S.
dc.contributor.authorInada, Natalia M.
dc.contributor.authorGrecco, Clovis
dc.contributor.authorMedeiros, Alexandra I. [UNESP]
dc.contributor.authorKurachi, Cristina
dc.contributor.authorBagnato, Vanderlei S.
dc.contributor.authorTearney, G. J.
dc.contributor.authorWang, T. D.
dc.contributor.authorSuter, M. J.
dc.contributor.authorLam, S.
dc.contributor.authorBrenner, M.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2019-10-03T18:18:16Z
dc.date.available2019-10-03T18:18:16Z
dc.date.issued2014-01-01
dc.description.abstractInfectious pneumonia is a major cause of morbidity and mortality, despite advances in diagnostics and therapeutics in pulmonary infections. One of the major difficulties associated with the infection comes from the high rate of antibiotic resistant microorganisms, claiming for the use of alternative techniques with high efficiency and low cost. The photodynamic inactivation (PDI) is emerging as one of the great possibilities in this area, once its action is oxidative, not allowing microorganism develops resistance against the treatment. PDI for decontamination pulmonary has potential for treatment or creating better conditions for the action of antibiotics. In this study, we are developing a device to implement PDI for the treatment of lung diseases with extracorporeal illumination. To validate our theory, we performed measurements in liquid phantom to simulate light penetration in biological tissues at various fluency rates, the temperature was monitored in a body of hairless mice and the measurements of light transmittance in this same animal model. A diode laser emitting at 810 nm in continuous mode was used. Our results show 70% of leakage at 0.5 mm of thickness in phantom model. The mouse body temperature variation was 5.4 degrees C and was observed light transmittance through its chest. These results are suggesting the possible application of the extracorporeal illumination using infrared light source. Based on these findings, further studies about photodynamic inactivation will be performed in animal model using indocyanine green and bacteriochlorin as photosensitizers. The pulmonary infection will be induced with Streptococcus pneumoniae and Klebsiella pneumoniae.en
dc.description.affiliationUniv Sao Paulo, Phys Inst Sao Carlos, Opt Grp, 400 Trabalhador Sancarlense Ave, BR-13566590 Sao Carlos, SP, Brazil
dc.description.affiliationUniv Fed Sao Carlos, BR-13565905 Sao Carlos, SP, Brazil
dc.description.affiliationSao Paulo State Univ, Immunol Lab, BR-17807901 Araraquara, SP, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Immunol Lab, BR-17807901 Araraquara, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent6
dc.identifierhttp://dx.doi.org/10.1117/12.2039366
dc.identifier.citationEndoscopic Microscopy Ix; And Optical Techniques In Pulmonary Medicine. Bellingham: Spie-int Soc Optical Engineering, v. 8927, 6 p., 2014.
dc.identifier.doi10.1117/12.2039366
dc.identifier.issn0277-786X
dc.identifier.urihttp://hdl.handle.net/11449/183902
dc.identifier.wosWOS:000335759900007
dc.language.isoeng
dc.publisherSpie-int Soc Optical Engineering
dc.relation.ispartofEndoscopic Microscopy Ix; And Optical Techniques In Pulmonary Medicine
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectPhotodynamic Inactivation
dc.subjectPhotosensitizer
dc.subjectPulmonary Diseases
dc.subjectExtracorporeal Illumination
dc.titlePulmonary decontamination for photodynamic inactivation with extracorporeal illuminationen
dc.typeTrabalho apresentado em evento
dcterms.rightsHolderSpie-int Soc Optical Engineering
dspace.entity.typePublication
unesp.author.lattes8756770929017974[5]
unesp.author.orcid0000-0002-1680-7728[4]
unesp.author.orcid0000-0001-6048-3647[5]

Arquivos

Coleções