Contributions on the use of Bismuth as internal standard for lead determinations using icp-based techniques

dc.contributor.authorBechlin, Marcos A. [UNESP]
dc.contributor.authorFerreira, Edilene C. [UNESP]
dc.contributor.authorNeto, José A. Gomes [UNESP]
dc.contributor.authorRamos, Juliano C.
dc.contributor.authorBorges, Daniel L. G.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)
dc.date.accessioned2018-12-11T16:39:13Z
dc.date.available2018-12-11T16:39:13Z
dc.date.issued2015-09-01
dc.description.abstractBismuth was evaluated as internal standard for Pb determinations and showed usefulness to minimize variations due to changes in the experimental conditions of the inductively coupled plasma optical emission spectrometry (ICP OES), inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Thirty four samples were analyzed and the Pb contents obtained by ICP-MS and ETV-ICP-MS were in agreement at 95% confidence level. Plant, biological tissue and soil reference materials were also analyzed and the results were close to certified values upon the use of the internal standard. Recoveries for Pb spikes (ICP OES: 95-110%; ICP-MS: 95-106%; ETV-ICP-MS: 92-119%) were better than those obtained with external calibration (ICP OES: 56-91%; ICP-MS: 36-136%; ETV.ICP-MS: 5-123%). The relative standard deviations (n = 12) was improved from 1-9% to 0.2-6% (ICP OES), from 0.5-11% to 0.1-7% (ICP-MS) and from 0.4-7% to 0.1-4% (ETV.ICP.MS) by using external and internal standard calibrations, respectively.en
dc.description.affiliationDepartamento de Química Analítica, Universidade Estadual Paulista (UNESP), Rua Prof. Francisco Degni, 55
dc.description.affiliationDepartamento de Química, Universidade Federal de Santa Catarina (UFSC), Campus Trindade
dc.description.affiliationUnespDepartamento de Química Analítica, Universidade Estadual Paulista (UNESP), Rua Prof. Francisco Degni, 55
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2012/13500-9
dc.format.extent1879-1886
dc.identifierhttp://dx.doi.org/10.5935/0103-5053.20150165
dc.identifier.citationJournal of the Brazilian Chemical Society, v. 26, n. 9, p. 1879-1886, 2015.
dc.identifier.doi10.5935/0103-5053.20150165
dc.identifier.fileS0103-50532015000901879.pdf
dc.identifier.issn1678-4790
dc.identifier.issn0103-5053
dc.identifier.scieloS0103-50532015000901879
dc.identifier.scopus2-s2.0-84941578493
dc.identifier.urihttp://hdl.handle.net/11449/168008
dc.language.isoeng
dc.relation.ispartofJournal of the Brazilian Chemical Society
dc.relation.ispartofsjr0,357
dc.relation.ispartofsjr0,357
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectBi internal standard
dc.subjectETV-ICP-MS
dc.subjectICP OES
dc.subjectICP-MS
dc.subjectLead determination
dc.titleContributions on the use of Bismuth as internal standard for lead determinations using icp-based techniquesen
dc.typeArtigo