Publicação:
Establishment of the epithelial attachment and connective tissue adaptation to implants installed under the concept of "platform switching": a histologic study in minipigs

dc.contributor.authorFarronato, Davide
dc.contributor.authorSantoro, Giacomo
dc.contributor.authorCanullo, Luigi
dc.contributor.authorBotticelli, Daniele
dc.contributor.authorMaiorana, Carlo
dc.contributor.authorLang, Niklaus P.
dc.contributor.institutionPrivate Practice
dc.contributor.institutionUniv Milan
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionARDEC
dc.contributor.institutionUniv Hong Kong
dc.date.accessioned2014-05-20T15:33:11Z
dc.date.available2014-05-20T15:33:11Z
dc.date.issued2012-01-01
dc.description.abstractAim: To validate the platform switching concept at oral implants with respect to the preservation of the alveolar crestal bone levels in an animal model. Material & methods: Five minipigs received three implants each with a 0.25mm implant/ abutment mismatch and were placed flush (T(0)), 1 mm below (T(1)) and 1 mm above (T(+1)) the alveolar bony crest, and as a control, one conventionally restored implant placed at the bone level. The implants were randomly inserted flapless into the mandible. Four months after implant insertion, the animals were sacrificed, and undecalcified block sections were obtained and used for histological analyses. Results: The mean values for peri- implant bone resorption were 1.09 +/- 0.59mm (Control), 0.51 (+/- 0.27 mm, T(0)), 0.50 (+/- 0.46 mm, T(1)) and 1.30 (+/- 0.21 mm, T (+1)), respectively. Statistically significant differences (P< 0.05) were found among the test (T(0), T(-1)) and the control sites. Control implants presented an average biologic width length of 3.20mm (+/- 0.33), with a connective tissue adaptation compartment of 1.29mm (+/- 0.53) and an epithelial attachment of 1.91 mm (+/- 0.71). T(0), T(1) and T(+1) implants presented with a mean biologic width of 1.97mm (+/- 1.20), 2.70 mm (+/- 1.36) and 2.84mm (+/- 0.90), respectively, with a connective tissue adaptation compartment of 1.21mm (+/- 0.97), 1.21 mm (+/- 0.65) and 1.50 mm (+/- 0.70) and an epithelial attachment of 0.84 mm (+/- 0.93), 1.66 mm (+/- 0.88) and 1.35 mm (+/- 0.44), respectively. Differences between the configurations were mainly associated with the length of the epithelial attachment. The epithelial attachment was significantly longer in the C sites than in T(0) (P = 0.014). However, no other differences between configurations were detected. Conclusion: If the implants are positioned at the level of the alveolar bony crest, the platform switching concept may have a minor impact on the length of the epithelial attachment (0.84 vs. 1.91 mm), while the connective tissue adaptation compartment remains relatively unaffected. Moreover, platform switching resulted in less resorption of the alveolar crest (0.58 mm).en
dc.description.affiliationPrivate Practice, I-00198 Rome, Italy
dc.description.affiliationUniv Milan, Fdn Policlin Ca Granda, Dept Implantol, Milan, Italy
dc.description.affiliationSão Paulo State Univ, UNESP Fac Dent Aracatuba, São Paulo, Brazil
dc.description.affiliationARDEC, Rimini, Italy
dc.description.affiliationUniv Hong Kong, Prince Philip Dent Hosp, Hong Kong, Hong Kong, Peoples R China
dc.description.affiliationUnespSão Paulo State Univ, UNESP Fac Dent Aracatuba, São Paulo, Brazil
dc.description.sponsorshipSweden & Martina srl, Due Carrare, PD, Italy
dc.format.extent90-94
dc.identifierhttp://dx.doi.org/10.1111/j.1600-0501.2011.02196.x
dc.identifier.citationClinical Oral Implants Research. Malden: Wiley-blackwell, v. 23, n. 1, p. 90-94, 2012.
dc.identifier.doi10.1111/j.1600-0501.2011.02196.x
dc.identifier.issn0905-7161
dc.identifier.urihttp://hdl.handle.net/11449/41888
dc.identifier.wosWOS:000298548900014
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofClinical Oral Implants Research
dc.relation.ispartofjcr4.305
dc.relation.ispartofsjr2,462
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectbiologic widthen
dc.subjectconnective tissue adaptationen
dc.subjectepithelial attachmenten
dc.subjecthealingen
dc.subjectoral implantsen
dc.subjectplatform switchingen
dc.titleEstablishment of the epithelial attachment and connective tissue adaptation to implants installed under the concept of "platform switching": a histologic study in minipigsen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções