Publicação: Calibration of frequency domain reflectometry sensors to estimate soil moisture in a geric xanthic ferralsol
dc.contributor.author | Abanto-Rodríguez, Carlos | |
dc.contributor.author | Araújo, Wellington Farias | |
dc.contributor.author | Chagas, Pollyana Cardoso | |
dc.contributor.author | Chagas, Edvan Alves | |
dc.contributor.author | João Lopes Monteiro, N. | |
dc.contributor.author | Siqueira, Raphael Da Silva | |
dc.contributor.author | Barbosa, Samara Martins [UNESP] | |
dc.contributor.author | Melo, Valdinar Ferreira | |
dc.contributor.author | Valero, Miguel A. Maffei | |
dc.contributor.institution | Universidade Federal de Roraima-UFRR | |
dc.contributor.institution | Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) | |
dc.contributor.institution | Instituto Federal de Roraima-IFRR | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2021-06-25T10:14:12Z | |
dc.date.available | 2021-06-25T10:14:12Z | |
dc.date.issued | 2020-01-01 | |
dc.description.abstract | The use of irrigation is essential to increase crop productivity; however, for efficient water management, it is necessary to more accurately estimate soil moisture. For this reason, the objective in this work was to calibrate FDR model 10HS frequency domain reflectometry sensors (Decagon Devices) for use in a Geric Xanthic Ferralsol type soil. For the calibration, non disturbed soil samples were collected in PVC pipes at two depths (0-20 and 20-40 cm), with four repetitions each and they were placed in trays with distilled water until saturation. Subsequently the sensors were introduced in the sample to obtain the moisture at the saturation point. Then, the samples were placed in an oven at 60 ºC, until they reached approximately 10 % humidity. The results showed that the gross volumetric moisture data recorded before calibration did not coincide with the 1:1 line, presenting divergent behavior, thus demonstrating the need for calibration. According to the results, it is concluded that the equations generated with the data before the calibration overestimated the volumetric soil moisture, and the equations obtained after the calibration satisfactorily measure the moisture of the Geric Xanthic Ferralsol type soil. | en |
dc.description.affiliation | Programa de Pós-graduação em Biodiversidade e Biotecnologia da Rede BIONORTE Universidade Federal de Roraima-UFRR | |
dc.description.affiliation | Universidade Federal de Roraima-UFRR | |
dc.description.affiliation | Empresa Brasileira de Pesquisa Agropecuaria-EMBRAPA Roraima | |
dc.description.affiliation | Programa de Pós-Graduação em Agronomia (POSAGRO) Universidade Federal de Roraima-UFRR | |
dc.description.affiliation | Instituto Federal de Roraima-IFRR | |
dc.description.affiliation | Universidade Estadual Paulista-UNESP | |
dc.description.affiliationUnesp | Universidade Estadual Paulista-UNESP | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 123-130 | |
dc.identifier.citation | Bioagro, v. 32, n. 2, p. 123-130, 2020. | |
dc.identifier.issn | 1316-3361 | |
dc.identifier.scopus | 2-s2.0-85093894303 | |
dc.identifier.uri | http://hdl.handle.net/11449/205370 | |
dc.language.iso | spa | |
dc.relation.ispartof | Bioagro | |
dc.source | Scopus | |
dc.subject | Additional Capacitance | |
dc.subject | Dielectric constant | |
dc.subject | Non-destructive methods | |
dc.title | Calibration of frequency domain reflectometry sensors to estimate soil moisture in a geric xanthic ferralsol | en |
dc.title | Calibración de sensores de reflectometría de dominio de frecuencia para estimar la humedad en un suelo geric xanthic ferralsol | es |
dc.type | Artigo | |
dspace.entity.type | Publication |