Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Internal standardization as a strategy to overcome non-spectral interferences in the determination of As, Cd and Pb in mineral fertilizers by synchronous vertical dual view (SVDV) ICP OES

dc.contributor.authorMacHado, Raquel C.
dc.contributor.authorSilva, Ana Beatriz S.
dc.contributor.authorAmaral, Clarice D. B.
dc.contributor.authorVirgilio, Alex [UNESP]
dc.contributor.authorNogueira, Ana Rita A.
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.contributor.institutionEmpresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
dc.contributor.institutionFederal University of Paraná
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-12T01:09:28Z
dc.date.available2020-12-12T01:09:28Z
dc.date.issued2019-01-07
dc.description.abstractElemental determination for fertilizer analysis by optical spectrometric techniques is often prone to non-spectral interferences due to the high content of easily ionizable elements (EIEs). Herein, we verify the use of internal standardization as a strategy for compensating for this matrix effect during As, Cd, and Pb determination in mineral fertilizers by SVDV ICP OES. Bismuth, Ir, Sc, and Y were chosen as internal standards (IS) and their ionic and atomic emission lines were carefully taken into account. The results indicated that the EIEs presence caused signal changes and internal standardization may be a suitable alternative to minimize this interference. By analyzing a certified reference material (CRM NIST 695) the best recoveries (from 94 to 106%) were achieved by applying internal standardization for all analytes. Concerning the elements evaluated as internal standards, Y (360.1 nm) and Sc (424.7 nm) were more suitable for As while Ir (215.8 nm) and Bi (190.2 nm and 195.4 nm) were suitable for Cd. For Pb, Ir (215.8 nm) was the most appropriate internal standard. The limits of detection using ISs were 0.70, 0.03 and 1.00 mg kg-1 for As, Cd and Pb, respectively. The application of internal standardization is an effective strategy to overcome matrix interferences in fertilizer analysis by SVDV ICP OES.en
dc.description.affiliationGroup for Applied Instrumental Analysis Department of Chemistry Federal University of São Carlos, P.O. Box 676
dc.description.affiliationEmbrapa Pecuária Sudeste, P.O. Box 339
dc.description.affiliationFederal University of Paraná Department of Chemistry
dc.description.affiliationSão Paulo State University UNESP, P.O. Box 355
dc.description.affiliationUnespSão Paulo State University UNESP, P.O. Box 355
dc.format.extent39-45
dc.identifierhttp://dx.doi.org/10.1039/c9ay02343g
dc.identifier.citationAnalytical Methods, v. 12, n. 1, p. 39-45, 2019.
dc.identifier.doi10.1039/c9ay02343g
dc.identifier.issn1759-9679
dc.identifier.issn1759-9660
dc.identifier.scopus2-s2.0-85076991430
dc.identifier.urihttp://hdl.handle.net/11449/198317
dc.language.isoeng
dc.relation.ispartofAnalytical Methods
dc.sourceScopus
dc.titleInternal standardization as a strategy to overcome non-spectral interferences in the determination of As, Cd and Pb in mineral fertilizers by synchronous vertical dual view (SVDV) ICP OESen
dc.typeArtigo

Arquivos

Coleções