Estudo da influência de diferentes resoluções de escaneamento de placas de fósforo de sistemas radiográficos digitais por meio da técnica de análise de textura
dc.contributor.advisor | Lopes, Sergio Lucio Pereira de Castro [UNESP] | |
dc.contributor.author | Beckmann, Pedro Santos [UNESP] | |
dc.contributor.coadvisor | Santos, Lana Ferreira | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2024-12-10T14:31:16Z | |
dc.date.available | 2024-12-10T14:31:16Z | |
dc.date.issued | 2024-11-26 | |
dc.description.abstract | Objetivo: Avaliar a influência de diferentes resoluções espaciais de escaneamento de placas de fósforo radiográficas pela da técnica de análise de textura (AT). Material e Métodos: foram realizadas radiografias digitais em sensores de uma escala de alumínio com 05 degraus (0,5mm de incremento), com tempos de exposição radiográficos de 0,10s, 0,20s. Estes foram escaneados em diferentes resoluções espaciais - 10, 20, 25 e 40 lp/mm - com 10 repetições para cada resolução. Nas imagens, no Software MaZda 4.6, foram determinadas regiões de interesse (ROI) envolvendo individualmente as imagens dos degraus de 0,5; 1,5 e 2,5mm. Foram calculados, pela matriz de co-orrência (COM) 11 parâmetros de textura de cada ROI. Realizada a análise exploratória dos dados e as resoluções espaciais foram comparadas em cada combinação de tempo e espessura pelo ANOVA, seguida do teste de comparações múltiplas de Tukey. Resultados: para o tempo de 0,10s, 08 parâmetros de textura, indicadores de menor homogeneidade (AngScMom; Contrast; InvDfMom; SumAverg; Entropy; DifVarnc; DifEntrp e Correlat), apresentaram diferenças estatisticamente significantes (p<0,05) entre as resoluções espaciais, independente da espessura da imagem, estes parâmetros assumiram maiores valores para resoluções entre 10 e 20lp/mm; para tempo de exposição de 0,20s, os parâmetros de textura Correlat e SumAverg, indicadores de menor uniformidade, apresentaram diferenças estatisticamente significantes (p<0,05) entre as resoluções espaciais estudadas, independente da espessura da imagem, com maiores valores para 10lp/mm e 20Lp/mm. Conclusões: Pela AT, menores resoluções de escaneamento suscitam em imagens com menor homogeneidade e uniformidade, independente da espessura do objeto. | pt |
dc.description.abstract | Objective: To assess the influence of different spatial resolutions in scanning radiographic phosphor plates using texture analysis (TA). Materials and Methods: Digital radiographs were acquired using sensors of an aluminum step wedge with 5 steps (0.5mm increment), with radiographic exposure times of 0.10s and 0.20s. These were scanned at different spatial resolutions - 10, 20, 25, and 40 lp/mm - with 10 repetitions for each resolution. In the images, regions of interest (ROIs) were determined using MaZda 4.6 software, individually encompassing images of the 0.5, 1.5, and 2.5mm steps. Eleven texture parameters of each ROI were calculated using the co-occurrence matrix (COM). Exploratory data analysis was performed, and spatial resolutions were compared in each combination of time and thickness using ANOVA, followed by Tukey's multiple comparison test. Results: For an exposure time of 0.10s, 8 texture parameters, indicative of lower homogeneity (AngScMom; Contrast; InvDfMom; SumAverg; Entropy; DifVarnc; DifEntrp, and Correlat), showed statistically significant differences (p<0.05) between spatial resolutions, regardless of image thickness, with these parameters assuming higher values for resolutions between 10 and 20 lp/mm. For an exposure time of 0.20s, the texture parameters Correlat and SumAverg, indicative of lower uniformity, showed statistically significant differences (p<0.05) between the spatial resolutions studied, regardless of image thickness, with higher values for 10 and 20 lp/mm. Conclusions: According to TA, lower scanning resolutions result in images with lower homogeneity and uniformity, regardless of the object thickness. | en |
dc.identifier.citation | Beckmann PS. Estudo da influência de diferentes resoluções de escaneamento de placas de fósforo de sistemas radiográficos digitais por meio da técnica de análise de textura [trabalho de conclusão de curso]. São José dos Campos (SP): Universidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia; 2024. | |
dc.identifier.lattes | 6361860961371089 | |
dc.identifier.uri | https://hdl.handle.net/11449/258781 | |
dc.language.iso | por | |
dc.publisher | Universidade Estadual Paulista (Unesp) | |
dc.rights.accessRights | Acesso restrito | pt |
dc.subject | Radiografia dentária | pt |
dc.subject | Processamento de imagem assistida por computador | pt |
dc.subject | Intensificação de Imagem Radiográfica | pt |
dc.subject | Radiography, dental | en |
dc.subject | Image processing, computer-assisted | en |
dc.subject | Radiographic image enhancement | en |
dc.title | Estudo da influência de diferentes resoluções de escaneamento de placas de fósforo de sistemas radiográficos digitais por meio da técnica de análise de textura | pt |
dc.title.alternative | Study of the influence of different scanning resolutions of phosphor plates in digital radiographic systems through texture analysis | en |
dc.type | Trabalho de conclusão de curso | pt |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.examinationboard.type | Banca pública | pt |
unesp.undergraduate | São José dos Campos - ICT - Odontologia | pt |
Arquivos
Pacote Original
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- beckman_ps_tcc_sjc.pdf
- Tamanho:
- 2.94 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 2.14 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- autorização_beckman_ps_tcc_sjc.pdf
- Tamanho:
- 145 KB
- Formato:
- Adobe Portable Document Format
- Descrição: