Publicação:
Determination of lead in the absence of supporting electrolyte using carbon fiber ultramicroelectrode without mercury film

dc.contributor.authorda Silva, S. M.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:53:18Z
dc.date.available2014-05-20T13:53:18Z
dc.date.issued1998-08-01
dc.description.abstractThe determination of lead ions directly in water, for application in analysis of samples of environmental interest, was studied by electroanalytical techniques. Linear sweep anodic stripping voltammetry with a carbon fiber disk ultramicroelectrode (7.0 mu m in diameter), without mercury film, has been used for lead determination, by standard addition, in purified water in the absence of supporting electrolyte. The response was linear in the range from 10.0 to 50.0 mu g L-1, with a detection limit of 0.8 mu g L-1, for 300 s preconcentration time, at -1.2 V and 1.0 V s(-1) scan rate. The reliability of the analytical procedure was evaluated by precision using relative standard deviations (5.6%, for three repetitive stripping current measurements of solution with 10.0 mu g L-1 lead ions) and by the accuracy with recovery experiments (mean of 110.8%) for the same concentration.en
dc.description.affiliationUNESP, Inst Biociencias, Dept Quim, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUnespUNESP, Inst Biociencias, Dept Quim, BR-18618000 Botucatu, SP, Brazil
dc.format.extent722-725
dc.identifierhttp://dx.doi.org/10.1002/(SICI)1521-4109(199808)10:10<722
dc.identifier.citationElectroanalysis. Berlin: Wiley-v C H Verlag Gmbh, v. 10, n. 10, p. 722-725, 1998.
dc.identifier.doi10.1002/(SICI)1521-4109(199808)10:10<722
dc.identifier.issn1040-0397
dc.identifier.urihttp://hdl.handle.net/11449/19016
dc.identifier.wosWOS:000075852200011
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofElectroanalysis
dc.relation.ispartofjcr2.851
dc.relation.ispartofsjr0,692
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectleadpt
dc.subjectwaterpt
dc.subjectultramicroelectrodespt
dc.subjectvoltammetrypt
dc.titleDetermination of lead in the absence of supporting electrolyte using carbon fiber ultramicroelectrode without mercury filmen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatupt
unesp.departmentQuímica e Bioquímica - IBBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: