Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Biomechanical evaluation of 3-unit fixed partial dentures on monotype and two-piece zirconia dental implants

dc.contributor.authorde Matos, Jefferson David Melo [UNESP]
dc.contributor.authorLopes, Guilherme da Rocha Scalzer [UNESP]
dc.contributor.authorNakano, Leonardo Jiro Nomura [UNESP]
dc.contributor.authorRamos, Nathália de Carvalho [UNESP]
dc.contributor.authorVasconcelos, John Eversong Lucena de
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.authorTribst, João Paulo Mendes [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade São Francisco (USF)
dc.contributor.institutionJuazeiro do Norte
dc.contributor.institutionUniversity of Taubaté (UNITAU)
dc.date.accessioned2022-05-01T09:30:47Z
dc.date.available2022-05-01T09:30:47Z
dc.date.issued2022-01-01
dc.description.abstractThis study aimed to evaluate the biomechanical behavior, stress distributions and bone microstrain of fixed partial dentures (FPD) with ceramic abutments supported on monotype zirconia implants, titanium implants and two-piece zirconia implants, using finite element analysis. A three-dimensional model of the jaw was simulated containing 1.0 mm thick cortical bone and cancellous bone tissue. A FPD and implant models (4.1 x 10 mm) were modeled containing a cement-retained implant abutment. These models were replicated in three groups with similar geometries: Titanium Implant and Zirconia Abutment (Ti-Zr); Zirconia Implant and Zirconia Abutment (Zr-Zr) and Monotype Zirconia Implant (Zr-S). An axial load of 300 N was applied to the center of the first premolar. The microstrain (με) and the Von-Mises stress (MPa) were assumed as failures criteria. For the three groups, a higher stress concentration was observed in the region of FPD connectors. The Ti-Zr group showed a higher stress concentration in the prosthesis and implant when compared to the other groups. However, the smaller elastic modulus of the titanium implant, in relation to the zirconia, provided a lower stress in the abutment and in the prosthetic screw. The monotype implant system allowed a more homogeneous stress distribution and its strain were predominantly located in the cervical region of the peri-implant bone tissue. Monotype or two-piece zirconia implants can be used for rehabilitation with FPD. However, the absence of separation between implant and abutment in the monotype system avoids the stress concentration in the prosthetic screw and reduced the peri-implant bone strain.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP)
dc.description.affiliationDepartment of Dentistry Universidade São Francisco (USF)
dc.description.affiliationDepartment of Implantology College of Denstristry CECAPE Juazeiro do Norte
dc.description.affiliationDepartment of Dentistry University of Taubaté (UNITAU)
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Institute of Science and Technology São Paulo State University (UNESP)
dc.format.extent239-246
dc.identifierhttp://dx.doi.org/10.1080/10255842.2021.1946798
dc.identifier.citationComputer Methods in Biomechanics and Biomedical Engineering, v. 25, n. 3, p. 239-246, 2022.
dc.identifier.doi10.1080/10255842.2021.1946798
dc.identifier.issn1476-8259
dc.identifier.issn1025-5842
dc.identifier.scopus2-s2.0-85115635500
dc.identifier.urihttp://hdl.handle.net/11449/233570
dc.language.isoeng
dc.relation.ispartofComputer Methods in Biomechanics and Biomedical Engineering
dc.sourceScopus
dc.subjectDental Abutments
dc.subjectDental Implants
dc.subjectDental Materials
dc.subjectFinite element analysis
dc.titleBiomechanical evaluation of 3-unit fixed partial dentures on monotype and two-piece zirconia dental implantsen
dc.typeArtigo
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos