Filling ability of three bioceramic root-end filling materials: A micro-computed tomography analysis

dc.contributor.authorToia, Cassia Cestari [UNESP]
dc.contributor.authorTeixeira, Fabricio Batista
dc.contributor.authorCucco, Carolina
dc.contributor.authorValera, Marcia Carneiro [UNESP]
dc.contributor.authorCavalcanti, Bruno Neves
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Iowa College of Dentistry and Dental Clinics
dc.date.accessioned2020-12-12T01:37:19Z
dc.date.available2020-12-12T01:37:19Z
dc.date.issued2020-01-01
dc.description.abstractThis study aimed at evaluating the volume of gaps and voids, and the total porosity percentage of three calcium-silicate-based materials in mandibular molars apicoectomy by Micro-CT analysis. Thirty-three mesial roots of extracted human mandibular molars were instrumented and obturated. The apical 3mm of each root was resected and prepared. Root-end cavities were filled with EndoSequence BC Putty (BC); ProRoot MTA (MTA) and Biodentine (BIO). Samples were scanned using a Micro-CT scanner and the tridimensional images reconstructed. Percentage of gaps (VG%) and of voids (VV%) were obtained. Porosity percentage (Po%) was also assessed. Data were analysed using Student’s t-test (P < 0.05). All materials presented gaps and voids. VG% was 2.006 (BC), 1.882 (MTA) and 1.450 (BIO), and VV% was 0.039 (BC), 0.021 (MTA) and 0.024 (BIO) with no statistical difference. Po% were 56.73 (BC), 51.94 (MTA) and 50.45 (BIO), with BC being statistically (P > 0.05) more porous.en
dc.description.affiliationEndodontics Division Department of Operative Dentistry Institute of Science and Technology São Paulo State University (UNESP)
dc.description.affiliationDepartment of Endodontics University of Iowa College of Dentistry and Dental Clinics
dc.description.affiliationUnespEndodontics Division Department of Operative Dentistry Institute of Science and Technology São Paulo State University (UNESP)
dc.identifierhttp://dx.doi.org/10.1111/aej.12434
dc.identifier.citationAustralian Endodontic Journal.
dc.identifier.doi10.1111/aej.12434
dc.identifier.issn1747-4477
dc.identifier.issn1329-1947
dc.identifier.scopus2-s2.0-85090312802
dc.identifier.urihttp://hdl.handle.net/11449/199347
dc.language.isoeng
dc.relation.ispartofAustralian Endodontic Journal
dc.sourceScopus
dc.subjectcalcium silicate
dc.subjectendodontic surgery
dc.subjectmicro-computed tomography
dc.subjectroot-end filling material
dc.titleFilling ability of three bioceramic root-end filling materials: A micro-computed tomography analysisen
dc.typeArtigo
unesp.author.orcid0000-0002-6460-5258[1]
unesp.author.orcid0000-0003-2790-3499[2]
unesp.author.orcid0000-0003-4355-5500[3]
unesp.author.orcid0000-0001-7398-6438[4]
unesp.author.orcid0000-0002-0455-4823[5]