Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry

dc.contributor.authorFreschi, GPG
dc.contributor.authorDakuzaku, C. S.
dc.contributor.authorde Moraes, M.
dc.contributor.authorNobrega, J. A.
dc.contributor.authorNeto, JAG
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)
dc.date.accessioned2014-05-20T15:22:20Z
dc.date.available2014-05-20T15:22:20Z
dc.date.issued2001-10-31
dc.description.abstractA method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l(-1) HNO3 and in 1 + 1 v/v diluted wine using mixtures of Pd(NO3)(2) + Mg(NO3)(2) and NH4H2PO4 + Mg(NO3)(2) as chemical modifiers. With 5 mug Pd + 3 mug Mg as the modifiers and a two-step pyrolysis (10 s at 400 degreesC and 10 s at 600 degreesC), the formation of carbonaceous residues inside the atomizer was avoided. For 20 mul of sample (wine + 0.056 mol l(-1) HNO3, 1 + 1, v/v) dispensed into the graphite tube, analytical curves in the 0.10-1.0 mug l(-1) Cd and 5.0-50 mug l(-1) Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 mug l(-1) for Cd, 0.8 mug l(-1) for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 mug l(-1) and for Pb at 500 mug l(-1). The relative standard deviations (n = 12) were typically < 8% for Cd and < 6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Ph was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level. (C) 2001 Elsevier B.V. B.V. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUniv Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.format.extent1987-1993
dc.identifierhttp://dx.doi.org/10.1016/S0584-8547(01)00331-7
dc.identifier.citationSpectrochimica Acta Part B-atomic Spectroscopy. Oxford: Pergamon-Elsevier B.V., v. 56, n. 10, p. 1987-1993, 2001.
dc.identifier.doi10.1016/S0584-8547(01)00331-7
dc.identifier.issn0584-8547
dc.identifier.urihttp://hdl.handle.net/11449/33331
dc.identifier.wosWOS:000172637600018
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofSpectrochimica Acta Part B-atomic Spectroscopy
dc.relation.ispartofjcr2.854
dc.relation.ispartofsjr0,960
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectsimultaneous graphite furnace atomic absorption spectrometrypt
dc.subjectwinept
dc.subjectdirect analysispt
dc.subjectcadmiumpt
dc.subjectleadpt
dc.titleSimultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometryen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
unesp.author.orcid0000-0001-9134-9547[4]

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções