Comparison of the quantification of caffeine in human plasma by gas chromatography and ELISA

dc.contributor.authorCarregaro, A.B. [UNESP]
dc.contributor.authorWoods, W.E.
dc.contributor.authorTobin, T.
dc.contributor.authorQueiroz-Neto, A. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Kentucky Department of Veterinary Science
dc.date.accessioned2014-05-20T13:15:43Z
dc.date.available2014-05-20T13:15:43Z
dc.date.issued2001-06-01
dc.description.abstractIn the present study we evaluated the precision of the ELISA method to quantify caffeine in human plasma and compared the results with those obtained by gas chromatography. A total of 58 samples were analyzed by gas chromatography using a nitrogen-phosphorus detector and routine techniques. For the ELISA test, the samples were diluted to obtain a concentration corresponding to 50% of the absorbance of the standard curve. To determine whether the proximity between the I50 of the standard curve and that of the sample would bring about a more precise result, the samples were divided into three blocks according to the criterion of difference, in modulus, of the I50 of the standard curve and of the I50 of the sample. The samples were classified into three groups. The first was composed of 20 samples with I50 up to 1.5 ng/ml, the second consisted of 21 samples with I50 ranging from 1.51 to 3 ng/ml, and the third of 17 samples with I50 ranging from 3.01 to 13 ng/ml. The determination coefficient (R² = 0.999) showed that the data obtained by gas chromatography represented a reliable basis. The results obtained by ELISA were also reliable, with an estimated Pearson correlation coefficient of 0.82 between the two methods. This coefficient for the different groups (0.88, 0.79 and 0.49 for groups 1, 2 and 3, respectively) showed greater reliability for the test with dilutions closer to I50.en
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Ciências Agrárias e Veterinárias Departamento de Morfologia e Fisiologia Animal
dc.description.affiliationUniversity of Kentucky Department of Veterinary Science
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Ciências Agrárias e Veterinárias Departamento de Morfologia e Fisiologia Animal
dc.format.extent821-824
dc.identifierhttp://dx.doi.org/10.1590/S0100-879X2001000600019
dc.identifier.citationBrazilian Journal of Medical and Biological Research. Associação Brasileira de Divulgação Científica, v. 34, n. 6, p. 821-824, 2001.
dc.identifier.doi10.1590/S0100-879X2001000600019
dc.identifier.fileS0100-879X2001000600019.pdf
dc.identifier.issn0100-879X
dc.identifier.scieloS0100-879X2001000600019
dc.identifier.urihttp://hdl.handle.net/11449/2781
dc.language.isoeng
dc.publisherAssociação Brasileira de Divulgação Científica (ABRADIC)
dc.relation.ispartofBrazilian Journal of Medical and Biological Research
dc.relation.ispartofjcr1.492
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectgas chromatographyen
dc.subjectELISAen
dc.subjectCaffeineen
dc.subjectplasmaen
dc.subjectquantificationen
dc.titleComparison of the quantification of caffeine in human plasma by gas chromatography and ELISAen
dc.typeArtigo
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt
unesp.departmentMorfologia e Fisiologia Animal - FCAVpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0100-879X2001000600019.pdf
Tamanho:
131.75 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: