Three-Dimensional Finite Element Analysis of Vertical and Angular Misfit in Implant-Supported Fixed Prostheses

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.authorRocha, Eduardo Passos [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:29:58Z
dc.date.accessioned2014-05-20T13:43:39Z
dc.date.available2013-09-30T18:29:58Z
dc.date.available2014-05-20T13:43:39Z
dc.date.issued2011-07-01
dc.description.abstractPurpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796en
dc.description.affiliationSão Paulo State Univ UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.format.extent788-796
dc.identifierhttp://www.quintpub.com/journals/omi/abstract.php?article_id=11241#.Ui9m5cbks_Y
dc.identifier.citationInternational Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 26, n. 4, p. 788-796, 2011.
dc.identifier.issn0882-2786
dc.identifier.lattes4438747643373395
dc.identifier.lattes3383392287039820
dc.identifier.urihttp://hdl.handle.net/11449/15245
dc.identifier.wosWOS:000294523900013
dc.language.isoeng
dc.publisherQuintessence Publishing Co Inc
dc.relation.ispartofInternational Journal of Oral & Maxillofacial Implants
dc.relation.ispartofjcr1.699
dc.relation.ispartofsjr1,576
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectabutment stressen
dc.subjectbiomechanicsen
dc.subjectdental implanten
dc.subjectdental prosthesisen
dc.subjectfinite element analysisen
dc.subjectimplant stressen
dc.titleThree-Dimensional Finite Element Analysis of Vertical and Angular Misfit in Implant-Supported Fixed Prosthesesen
dc.typeArtigo
dcterms.licensehttp://www.quintpub.com/journals/jop/orderreprints.php
dcterms.rightsHolderQuintessence Publishing Co Inc
unesp.author.lattes4438747643373395
unesp.author.lattes3383392287039820
unesp.author.orcid0000-0002-8903-0737[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: