Load-application devices: a comparative strain gauge analysis

dc.contributor.authorNishioka, Renato Sussumu
dc.contributor.authorVasconcellos, Luis Gustavo Oliveira De
dc.contributor.authorJóias, Renata Pilli
dc.contributor.authorRode, Sigmar de Mello
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-08-26T19:19:21Z
dc.date.available2015-08-26T19:19:21Z
dc.date.issued2015-06-01
dc.description.abstractIn view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.en
dc.description.abstractConsiderando os valores relativamente pequenos utilizados em odontologia para os ensaios de carregamento verticais axiais, foi desenvolvido um dispositivo de aplicação de carga (DAC) para substituir a máquina de ensaios universal (EMIC). O objetivo deste estudo foi desenvolver um DAC e compará-lo com a EMIC por meio da utilização de carregamentos axiais e não-axiais. Num bloco de poliuretano foi inserido um implante hexágono externo, o qual foi conectado a um pilar protético esteticone. Sobre o pilar protético foi parafusada uma coifa plástica e um pilar cônico foi modelado em resina acrílica, que foi moldada para a obtenção de dez enceramentos iguais que foram fundidos em níquel cromo. Quatro extensômetros foram diametralmente colados ao redor do implante. Cada corpo de prova foi submetido a cargas axiais central (C) e lateral (L) de 30 kgf, em ambos os dispositivos: G1) DAC/C; G2) DAC/L; G3) EMIC/C; G4) EMIC/L. Os dados (µε) foram analisados estatisticamente pelos testes de ANOVA para medidas repetidas e de Tukey (p<0,05). Não houve diferença estatisticamente significante entre os dispositivos DAC e EMIC, independente do tipo de carga. A aplicação de carga não-axial (NA) determinou um aumento significante de tensões ao redor do implante. Foi concluído que o DAC é uma opção confiável, a qual induz microtensão em implantes de forma semelhante à EMIC.pt
dc.description.affiliationUniversidade Estadual Paulista São José dos Campos Dental School Department of Dental Materials and Prosthodontics
dc.description.affiliationUniversidade Estadual Paulista São José dos Campos Dental School Department of Bioscience and Oral Diagnosis
dc.description.affiliationUnespUniversidade Estadual Paulista São José dos Campos Dental School Department of Dental Materials and Prosthodontics
dc.description.affiliationUnespUniversidade Estadual Paulista São José dos Campos Dental School Department of Bioscience and Oral Diagnosis
dc.format.extent258-262
dc.identifierhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258&lng=en&nrm=iso&tlng=en
dc.identifier.citationBrazilian Dental Journal, v. 26, n. 3, p. 258-262, 2015.
dc.identifier.doi10.1590/0103-6440201300321
dc.identifier.fileS0103-64402015000300258.pdf
dc.identifier.issn0103-6440
dc.identifier.lattes0056660842284397
dc.identifier.lattes3422118958429909
dc.identifier.orcid0000-0002-1458-601X
dc.identifier.scieloS0103-64402015000300258
dc.identifier.urihttp://hdl.handle.net/11449/127366
dc.language.isoeng
dc.publisherFundação Odontológica de Ribeirão Preto
dc.relation.ispartofBrazilian Dental Journal
dc.relation.ispartofsjr0,476
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectDental implantsen
dc.subjectDental prosthesisen
dc.subjectImplant-supported dental prosthesisen
dc.titleLoad-application devices: a comparative strain gauge analysisen
dc.typeArtigo
unesp.author.lattes3422118958429909
unesp.author.lattes0056660842284397[1]
unesp.author.orcid0000-0002-4261-4217[4]
unesp.author.orcid0000-0002-1458-601X[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentBiociências e Diagnóstico Bucal - ICTpt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-64402015000300258.pdf
Tamanho:
570.55 KB
Formato:
Adobe Portable Document Format