Publicação:
Monte Carlo simulation applied in total reflection X-ray fluorescence: Preliminary results

dc.contributor.authorMeira, Luiza L. C. [UNESP]
dc.contributor.authorInocente, Guilherme F. [UNESP]
dc.contributor.authorVieira, Letícia D. [UNESP]
dc.contributor.authorMesa, Joel [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:29:30Z
dc.date.available2014-05-27T11:29:30Z
dc.date.issued2013-05-20
dc.description.abstractThe X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method. © 2013 AIP Publishing LLC.en
dc.description.affiliationDepartamento de Física e Biofísica Instituto de Biociências de Botucatu Universidade Estadual Paulista Júlio de Mesquita Filho
dc.description.affiliationUnespDepartamento de Física e Biofísica Instituto de Biociências de Botucatu Universidade Estadual Paulista Júlio de Mesquita Filho
dc.format.extent66-69
dc.identifierhttp://dx.doi.org/10.1063/1.4804085
dc.identifier.citationAIP Conference Proceedings, v. 1529, p. 66-69.
dc.identifier.doi10.1063/1.4804085
dc.identifier.issn0094-243X
dc.identifier.issn1551-7616
dc.identifier.scopus2-s2.0-84877774538
dc.identifier.urihttp://hdl.handle.net/11449/75415
dc.identifier.wosWOS:000319754400012
dc.language.isoeng
dc.relation.ispartofAIP Conference Proceedings
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectDiagnostic X-ray
dc.subjectMonte Carlo Simulation
dc.subjectSynchrotron Radiation
dc.subjectTXRF
dc.titleMonte Carlo simulation applied in total reflection X-ray fluorescence: Preliminary resultsen