Publicação:
Application of wavelets to the evaluation of phantom images for mammography quality control

dc.contributor.authorAlvarez, M. [UNESP]
dc.contributor.authorMiranda, Diana Rodrigues de Pina [UNESP]
dc.contributor.authorMiranda, J. R. A. [UNESP]
dc.contributor.authorDuarte, S. B.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionMCT
dc.date.accessioned2014-05-20T13:34:31Z
dc.date.available2014-05-20T13:34:31Z
dc.date.issued2012-11-07
dc.description.abstractThe main goal of this work was to develop a methodology for the computed analysis of American College of Radiology (ACR) mammographic phantom images, to be used in a quality control (QC) program of mammographic services. Discrete wavelet transform processing was applied to enhance the quality of images from the ACR mammographic phantom and to allow a lower dose for automatic evaluations of equipment performance in a QC program. Regions of interest (ROIs) containing phantom test objects (e. g., masses, fibers and specks) were focalized for appropriate wavelet processing, which highlighted the characteristics of structures present in each ROI. To minimize false-positive detection, each ROI in the image was submitted to pattern recognition tests, which identified structural details of the focalized test objects. Geometric and morphologic parameters of the processed test object images were used to quantify the final level of image quality. The final purpose of this work was to establish the main computational procedures for algorithms of quality evaluation of ACR phantom images. These procedures were implemented, and satisfactory agreement was obtained when the algorithm scores for image quality were compared with the results of assessments by three experienced radiologists. An exploratory study of a potential dose reduction was performed based on the radiologist scores and on the algorithm evaluation of images treated by wavelet processing. The results were comparable with both methods, although the algorithm had a tendency to provide a lower dose reduction than the evaluation by observers. Nevertheless, the objective and more precise criteria used by the algorithm to score image quality gave the computational result a higher degree of confidence. The developed algorithm demonstrates the potential use of the wavelet image processing approach for objectively evaluating the mammographic image quality level in routine QC tests. The implemented computational procedures could also enable the performance of advanced analyses to study potential dose reduction in a routine service.en
dc.description.affiliationUNESP Univ Estadual Paulista, Inst Biociencias Botucatu, Dept Fis & Biofis, BR-18618000 São Paulo, Brazil
dc.description.affiliationUNESP Univ Estadual Paulista, Dept Doencas Tropicais & Diagnost Imagem, Fac Med Botucatu, BR-18618000 São Paulo, Brazil
dc.description.affiliationMCT, CBPF, BR-22290180 Rio de Janeiro, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Inst Biociencias Botucatu, Dept Fis & Biofis, BR-18618000 São Paulo, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Dept Doencas Tropicais & Diagnost Imagem, Fac Med Botucatu, BR-18618000 São Paulo, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent7177-7190
dc.identifierhttp://dx.doi.org/10.1088/0031-9155/57/21/7177
dc.identifier.citationPhysics In Medicine and Biology. Bristol: Iop Publishing Ltd, v. 57, n. 21, p. 7177-7190, 2012.
dc.identifier.doi10.1088/0031-9155/57/21/7177
dc.identifier.issn0031-9155
dc.identifier.urihttp://hdl.handle.net/11449/11840
dc.identifier.wosWOS:000310528700031
dc.language.isoeng
dc.publisherIop Publishing Ltd
dc.relation.ispartofPhysics In Medicine and Biology
dc.relation.ispartofjcr2.665
dc.relation.ispartofsjr1,263
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleApplication of wavelets to the evaluation of phantom images for mammography quality controlen
dc.typeArtigo
dcterms.rightsHolderIop Publishing Ltd
dspace.entity.typePublication
unesp.author.orcid0000-0002-8306-8056[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatupt
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.departmentDoenças Tropicais e Diagnósticos por Imagem - FMBpt
unesp.departmentFísica e Biofísica - IBBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: