Avaliação da eficiência de dois programas na eliminação de ruído para técnica de subtração

dc.contributor.advisorMoraes, Mari Eli Leonelli de [UNESP]
dc.contributor.advisorOno, Evelise [UNESP]
dc.contributor.authorSoares, Milton Gonçalves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:35:10Z
dc.date.available2014-06-11T19:35:10Z
dc.date.issued2009-02-20
dc.description.abstractO objetivo neste trabalho foi comparar, por meio da técnica de subtração radiográfica digital (SRD), a qualidade do registro a posteriori de 2 programas de computador. Para isso foi utilizada amostra de 294 radiografias periapicais digitais diretas. Essa amostra foi obtida de estudo anterior, no qual foram radiografados 49 dentes de mandíbulas maceradas, das regiões de incisivos centrais, laterais, caninos e prémolares. Cada dente foi radiografado com 6 diferentes ângulos de projeção, sendo: 0° de ângulo horizontal com 0°, 10° e 20° de ângulo vertical, e 10° de ângulo horizontal com 0°, 10° e 20° de ângulo vertical. As imagens radiográficas foram inseridas nos programas EMAGO® e Regeemy para os registros. Em seguida as SRD foram realizadas no programa Image Tool versão 1.27. A qualidade do registro das imagens foi avaliada por meio dos valores do desvio-padrão (DP) dos níveis de cinza das imagens subtraídas, o (DP) dos níveis de cinza serve como parâmetro para determinar o ruído nas imagens subtraídas. Para isso foi utilizado o programa Adobe Photoshop versão 7.0. A comparação dos valores do ruído das imagens subtraídas (desvio-padrão dos níveis de cinza) foi realizada pelo teste t pareado com nível de significância de 5%. Pelos resultados, verificou-se diferença estatisticamente significantes entre os 2 programas para todas as variações de ângulos de projeção estudadas, com valores maiores no DP quando se utilizou o programa EMAGO®. Visto que as imagens registradas pelo programa Regeemy resultaram em imagens subtraídas com menor desvio padrão de tons de cinza, conclui-se que esse programa apresentou melhor performance no registros de imagens para a técnica de subtração.pt
dc.description.abstractThe aim of this study was to compare the quality of image registration of two computer programs by means of digital subtraction radiography (DSR). The sample comprised 294 direct digital periapical radiographs. This sample was obtained from a previous study in which 49 mandibular teeth (central incisors, laterals incisors, cuspids and bicuspids), were radiographed with 6 different x-ray beam angles: 0° horizontal with 0°, 10° and 20° vertical, and 10° horizontal with 0°, 10° and 20° vertical. The radiographs were registered with EMAGO and Regeemy. The registered images were subtracted from their respective reference images with Image Tool 1.27. The quality of the registered images was evaluated by the mean values of the standard deviation (SD) of gray levels on the subtracted images,using the histogram tool of Adobe Photoshop 7.0. Paired t-test was adopted to compare the mean SD for the gray levels between Reegemy and Emago. The results demonstrated statistically significant differences on the quality of image registrations of the programs for all variations of angle. Higher SD was found for the subtractions obtained with registered images of EMAGO®. The SD for gray levels is the usual parameter for evaluation of image noise on subtracted images. Since lower SD was observed for the gray levels of subtractions obtained with registered images from Reegemy, we concluded that Regeemy achieved better performance on image registration for the subtraction techinique.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent89 f. : il.
dc.identifier.aleph000585871
dc.identifier.capes33004145081P0
dc.identifier.citationSOARES, Milton Gonçalves. Avaliação da eficiência de dois programas na eliminação de ruído para técnica de subtração. 2009. 89 f. Tese (doutorado) – Universidade Estadual Paulista, Faculdade de Odontologia de São José dos Campos, 2009.
dc.identifier.filesoares_mg_dr_sjc.pdf
dc.identifier.lattes0450226572005125
dc.identifier.urihttp://hdl.handle.net/11449/105876
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.sourceAleph
dc.subjectRadiografiapt
dc.subjectMandíbulapt
dc.subjectDiagnóstico por imagempt
dc.subjectTécnica de subtraçãopt
dc.subjectComputer-Assisteden
dc.titleAvaliação da eficiência de dois programas na eliminação de ruído para técnica de subtraçãopt
dc.typeTese de doutorado
unesp.author.lattes0450226572005125
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.graduateProgramBiopatologia Bucal - ICTpt
unesp.knowledgeAreaRadiologia odontológicapt
unesp.researchAreaUso e aplicações de equipamentos, materiais e técnicas radiográficas em Odontologia (Use and application of equipment, materials and radiographic techniques in dentistry)pt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
soares_mg_dr_sjc.pdf
Tamanho:
660.26 KB
Formato:
Adobe Portable Document Format