Stress distribution on short implants with different designs: a photoelastic analysis

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorde Medeiros, Rodrigo Antonio [UNESP]
dc.contributor.authorSônego, Mariana Vilela [UNESP]
dc.contributor.authorde Lima, Taynara Maria Toito [UNESP]
dc.contributor.authorPesqueira, Aldiéris Alves [UNESP]
dc.contributor.authordos Santos, Daniela Micheline [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:06:20Z
dc.date.available2018-12-11T17:06:20Z
dc.date.issued2017-02-17
dc.description.abstractShort dental implants have been used as an attempt to avoid bone grafts surgery, however there are few literature reports that evaluate changes to their design. Therefore, the aim of this study was to assess the effect of different short implant design on stress distribution through photoelastic analysis. Six external hexagon (5 × 5 mm) short dental implants with different design were used. Each group was treated with a single crown and a three element fixed partial dental prosthesis, resulting in a total of 12 photoelastic models. The assembling photoelastic model-implant-prosthesis was set in a circular polariscope where loads of 100N were applied on the occlusal surface with a Universal Test Machine (UTM). The tension fringes were photographed and later assessed qualitatively by a graphic software (Adobe Photoshop). Less high-intensity fringes were observed on the short implants with triangular threads, short external hexagon and flat apical profile. In conclusion, the macrodesign influenced the amount of stress distributed to the bone when short dental implants are placed.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Aracatuba Dental School São Paulo State University (UNESP)
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Aracatuba Dental School São Paulo State University (UNESP)
dc.format.extent115-121
dc.identifierhttp://dx.doi.org/10.1080/03091902.2016.1239276
dc.identifier.citationJournal of Medical Engineering and Technology, v. 41, n. 2, p. 115-121, 2017.
dc.identifier.doi10.1080/03091902.2016.1239276
dc.identifier.issn1464-522X
dc.identifier.issn0309-1902
dc.identifier.lattes9719883814872582
dc.identifier.scopus2-s2.0-84990216649
dc.identifier.urihttp://hdl.handle.net/11449/173569
dc.language.isoeng
dc.relation.ispartofJournal of Medical Engineering and Technology
dc.relation.ispartofsjr0,389
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectbiomechanics
dc.subjectDental implants
dc.subjectfixed partial prosthesis
dc.titleStress distribution on short implants with different designs: a photoelastic analysisen
dc.typeArtigo
unesp.author.lattes2336450644149867[5]
unesp.author.lattes9719883814872582
unesp.author.orcid0000-0003-3020-5253[5]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araçatubapt