Effect of microwave disinfection on the surface roughness of three denture base resins after tooth brushing
dc.contributor.author | Izumida, Fernanda Emiko [UNESP] | |
dc.contributor.author | Ribeiro, Roberta Chuqui [UNESP] | |
dc.contributor.author | Giampaolo, Eunice Teresinha [UNESP] | |
dc.contributor.author | Machado, Ana Lucia [UNESP] | |
dc.contributor.author | Pavarina, Ana Claudia [UNESP] | |
dc.contributor.author | Vergani, Carlos Eduardo [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:46:39Z | |
dc.date.available | 2014-05-20T13:46:39Z | |
dc.date.issued | 2011-12-01 | |
dc.description.abstract | Objective: This study investigated the effect of microwave disinfection on the roughness of three heat-polymerised acrylic resins after tooth brushing. Background: Microwave disinfection has been recommended to reduce cross-contamination. However, this procedure may also influence the physical and mechanical properties of acrylic resins. Materials and methods: Specimens (40 x 20 x 2 mm) of resins: Lucitone 550 (L), QC 20(QC) and Acron MC (A) were prepared and divided into four groups (n = 10): Control groups 1 (C1) and 2 (C2) stored in water for 48 h or 7 days; Test groups 1 (MW2) and 2 (MW7) stored in water for 48 h and disinfected (650 W for 6 min) daily for 2 or 7 days, respectively. After treatments, the specimens were placed in a tooth brushing machine at a rate of 60 reciprocal strokes per minute. The specimens were brushed with 20 000 strokes, which represent approximately 2 years of denture cleansing. The surface roughness (Ra) was evaluated before and after the tooth brushing. Data were analysed by two-way anova and Tukey Honestly Significant Difference (HSD) post hoc tests (alpha = 0.05). Results: The data revealed significant changes between test groups for A and L resins. Comparison among resins revealed that for MW7, the roughness of A was significantly lower than that of L. After the seven microwave cycles, it could be seen that the roughness values of QC were significantly lower than those of L. Conclusions: The roughness of QC after brushing was not significantly affected by microwave disinfection. For A and L, seven microwave cycles resulted in increased roughness. | en |
dc.description.affiliation | Univ Estadual Paulista, Dept Dent Mat & Prosthodont, Sch Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Dent Mat & Prosthodont, Sch Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 04/03821-6 | |
dc.format.extent | 277-282 | |
dc.identifier | http://dx.doi.org/10.1111/j.1741-2358.2010.00393.x | |
dc.identifier.citation | Gerodontology. Malden: Wiley-blackwell, v. 28, n. 4, p. 277-282, 2011. | |
dc.identifier.doi | 10.1111/j.1741-2358.2010.00393.x | |
dc.identifier.issn | 0734-0664 | |
dc.identifier.lattes | 5737127334248549 | |
dc.identifier.lattes | 8000248781842587 | |
dc.identifier.lattes | 8867670539105403 | |
dc.identifier.lattes | 3003130522427820 | |
dc.identifier.orcid | 0000-0002-7375-4714 | |
dc.identifier.uri | http://hdl.handle.net/11449/16527 | |
dc.identifier.wos | WOS:000297212000007 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Gerodontology | |
dc.relation.ispartofjcr | 1.439 | |
dc.relation.ispartofsjr | 0,627 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | acrylic resins | en |
dc.subject | tooth brushing | en |
dc.subject | abrasion | en |
dc.subject | microwave disinfection | en |
dc.title | Effect of microwave disinfection on the surface roughness of three denture base resins after tooth brushing | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-blackwell | |
unesp.author.lattes | 5737127334248549 | |
unesp.author.lattes | 8000248781842587[4] | |
unesp.author.lattes | 8867670539105403[5] | |
unesp.author.lattes | 3003130522427820[6] | |
unesp.author.orcid | 0000-0002-7375-4714[6] | |
unesp.author.orcid | 0000-0002-9231-1994[5] | |
unesp.author.orcid | 0000-0002-2718-428X[4] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: