Publicação:
Effects of contrast material on computed tomographic measurements of lung volumes in patients with acute lung injury

dc.contributor.authorBouhemad, Bélaid
dc.contributor.authorPuybasset, L.
dc.contributor.authorCoriat, P.
dc.contributor.authorRoussat, M. O.
dc.contributor.authorGoldstein, I.
dc.contributor.authorNieszkowska, A.
dc.contributor.authorRichecoeur, Jack
dc.contributor.authorLu, Qin
dc.contributor.authorMalbouisson, Luiz M.
dc.contributor.authorCluzel, Philippe
dc.contributor.authorRouby, Jean-Jacques
dc.contributor.authorGusman, P. [UNESP]
dc.contributor.authorVieira, S.
dc.contributor.authorElman, M.
dc.contributor.institutionUniversity of Paris VI
dc.contributor.institutionHosp./Reanim. Med. Polyval. Pontoise
dc.contributor.institutionHospital das Clinicas
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal do Rio Grande do Sul (UFRGS)
dc.contributor.institutionFac. de Ciencias Med. de Santa Casa
dc.contributor.institutionHopital de la Pitie-Salpetriere
dc.date.accessioned2014-05-27T11:20:36Z
dc.date.available2014-05-27T11:20:36Z
dc.date.issued2003-02-01
dc.description.abstractBackground. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.en
dc.description.affiliationReanimation Chirurg. Pierre Viars Hospital Pitie-Salpetriere University of Paris VI, Paris
dc.description.affiliationHosp./Reanim. Med. Polyval. Pontoise, Pontoise
dc.description.affiliationDepartment of Anaesthesiology Hospital das Clinicas, São Paulo
dc.description.affiliationDepartment of Radiology Hospital Pitie-Salpetriere University of Paris VI, Paris
dc.description.affiliationDepartment of Anesthesiology UNESP, Botucatu
dc.description.affiliationHosp. de Clinicas de Porto Allegre UFRGS, Porto Allegre
dc.description.affiliationDepartment of Anesthesiology Fac. de Ciencias Med. de Santa Casa, São Paulo
dc.description.affiliationUnite Reanim. Chirurg. Pierre Viars Hopital de la Pitie-Salpetriere, Paris
dc.description.affiliationUnespDepartment of Anesthesiology UNESP, Botucatu
dc.format.extent63-71
dc.identifierhttp://dx.doi.org/10.1186/cc1852
dc.identifier.citationCritical Care, v. 7, n. 1, p. 63-71, 2003.
dc.identifier.doi10.1186/cc1852
dc.identifier.file2-s2.0-12244259112.pdf
dc.identifier.issn1364-8535
dc.identifier.scopus2-s2.0-12244259112
dc.identifier.urihttp://hdl.handle.net/11449/67188
dc.language.isoeng
dc.relation.ispartofCritical Care
dc.relation.ispartofsjr2,480
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectAcute lung injury
dc.subjectContrast material
dc.subjectLung volumes
dc.subjectThoracic computed tomography scan
dc.subjectcontrast medium
dc.subjectadult
dc.subjectaged
dc.subjectartifact
dc.subjectattenuation
dc.subjectclinical article
dc.subjectcomputer assisted tomography
dc.subjectcomputer program
dc.subjectcontrast enhancement
dc.subjectcontrolled study
dc.subjectcritical illness
dc.subjectdose response
dc.subjectexpiratory flow
dc.subjectfemale
dc.subjecthuman
dc.subjecthypothesis
dc.subjectlung extravascular fluid
dc.subjectlung injury
dc.subjectlung parenchyma
dc.subjectlung volume
dc.subjectmale
dc.subjectmeasurement
dc.subjectpleura effusion
dc.subjectpriority journal
dc.subjectreview
dc.subjecttreatment indication
dc.subjectAdult
dc.subjectAged
dc.subjectAged, 80 and over
dc.subjectContrast Media
dc.subjectExtravascular Lung Water
dc.subjectFemale
dc.subjectHumans
dc.subjectInjections, Intravenous
dc.subjectLung Volume Measurements
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectRadiographic Image Enhancement
dc.subjectRespiratory Distress Syndrome, Adult
dc.subjectTomography, Spiral Computed
dc.titleEffects of contrast material on computed tomographic measurements of lung volumes in patients with acute lung injuryen
dc.typeArtigo
dcterms.licensehttp://www.biomedcentral.com/about/license
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.departmentAnestesiologia - FMBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-12244259112.pdf
Tamanho:
145.57 KB
Formato:
Adobe Portable Document Format