The effect of splint material rigidity in implant impression techniques
dc.contributor.author | Del’Acqua, Marcelo Antonialli | |
dc.contributor.author | Chávez, Alejandro Muñoz [UNESP] | |
dc.contributor.author | Castanharo, Sabrina Maria [UNESP] | |
dc.contributor.author | Compagnoni, Marco Antonio [UNESP] | |
dc.contributor.author | de Assis Mollo, Francisco [UNESP] | |
dc.contributor.institution | Araraquara University Center-UNIARA | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.date.accessioned | 2022-04-28T22:13:40Z | |
dc.date.available | 2022-04-28T22:13:40Z | |
dc.date.issued | 2010-01-01 | |
dc.description.abstract | Purpose: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group’s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at × 100 magnification. The results were analyzed statistically (t test). Results: The mean values of abutment/framework interface gaps were: master cast = 32 µm (SD 2), group D =165 µm (SD 60), and group M = 69 µm (SD 36). There was a statistically significant difference between the D and M groups (P = .001). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings. © 2010 by Quintessence Publishing Co Inc. | en |
dc.description.affiliation | Araraquara University Center-UNIARA, Araraquara, São Paulo | |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo | |
dc.format.extent | 1153-1158 | |
dc.identifier.citation | International Journal of Oral and Maxillofacial Implants, v. 25, n. 6, p. 1153-1158, 2010. | |
dc.identifier.issn | 0882-2786 | |
dc.identifier.scopus | 2-s2.0-79952296180 | |
dc.identifier.uri | http://hdl.handle.net/11449/226257 | |
dc.language.iso | eng | |
dc.relation.ispartof | International Journal of Oral and Maxillofacial Implants | |
dc.source | Scopus | |
dc.subject | Dental implant | |
dc.subject | Implant impression technique | |
dc.subject | Splinting material | |
dc.title | The effect of splint material rigidity in implant impression techniques | en |
dc.type | Artigo | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |