The effect of splint material rigidity in implant impression techniques

dc.contributor.authorDel’Acqua, Marcelo Antonialli
dc.contributor.authorChávez, Alejandro Muñoz [UNESP]
dc.contributor.authorCastanharo, Sabrina Maria [UNESP]
dc.contributor.authorCompagnoni, Marco Antonio [UNESP]
dc.contributor.authorde Assis Mollo, Francisco [UNESP]
dc.contributor.institutionAraraquara University Center-UNIARA
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-28T22:13:40Z
dc.date.available2022-04-28T22:13:40Z
dc.date.issued2010-01-01
dc.description.abstractPurpose: This in vitro study compared the dimensional accuracy of two impression techniques: Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant-supported prostheses. Materials and Methods: A master cast with four parallel implant abutment analogs and a passive framework were fabricated. Vinyl polysiloxane impression material was used for all impressions with a metal stock tray. Two groups (D and M) were tested (n = 5). The measurement method employed was just one titanium screw tightened to the framework. Each group’s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at × 100 magnification. The results were analyzed statistically (t test). Results: The mean values of abutment/framework interface gaps were: master cast = 32 µm (SD 2), group D =165 µm (SD 60), and group M = 69 µm (SD 36). There was a statistically significant difference between the D and M groups (P = .001). Conclusion: Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings. © 2010 by Quintessence Publishing Co Inc.en
dc.description.affiliationAraraquara University Center-UNIARA, Araraquara, São Paulo
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araraquara Dental School São Paulo State University, Araraquara, São Paulo
dc.format.extent1153-1158
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants, v. 25, n. 6, p. 1153-1158, 2010.
dc.identifier.issn0882-2786
dc.identifier.scopus2-s2.0-79952296180
dc.identifier.urihttp://hdl.handle.net/11449/226257
dc.language.isoeng
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implants
dc.sourceScopus
dc.subjectDental implant
dc.subjectImplant impression technique
dc.subjectSplinting material
dc.titleThe effect of splint material rigidity in implant impression techniquesen
dc.typeArtigo
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos