Accuracy of Digital Images in the Detection of Marginal Micro leakage: An In Vitro Study
dc.contributor.author | Alvarenga, Fabio Augusto de Santi [UNESP] | |
dc.contributor.author | Andrade, Marcelo Ferrarezi de [UNESP] | |
dc.contributor.author | Pinelli, Camila [UNESP] | |
dc.contributor.author | Rastelli, Alessandra Nara de Souza [UNESP] | |
dc.contributor.author | Victorino, Keli Regina [UNESP] | |
dc.contributor.author | Monteiro Loffredo, Leonor de Castro [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:46:58Z | |
dc.date.available | 2014-05-20T13:46:58Z | |
dc.date.issued | 2012-08-01 | |
dc.description.abstract | Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific. | en |
dc.description.affiliation | São Paulo State Univ UNESP, Araraquara Dent Sch, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliation | São Paulo State Univ UNESP, Araraquara Dent Sch, Dept Social Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliation | São Paulo State Univ UNESP, Araraquara Dent Sch, Restorat Dent Grad Program, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Araraquara Dent Sch, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Araraquara Dent Sch, Dept Social Dent, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Araraquara Dent Sch, Restorat Dent Grad Program, BR-14801903 Araraquara, SP, Brazil | |
dc.format.extent | 335-338 | |
dc.identifier | http://dx.doi.org/10.3290/j.jad.a22713 | |
dc.identifier.citation | Journal of Adhesive Dentistry. Hanover Park: Quintessence Publishing Co Inc, v. 14, n. 4, p. 335-338, 2012. | |
dc.identifier.doi | 10.3290/j.jad.a22713 | |
dc.identifier.issn | 1461-5185 | |
dc.identifier.lattes | 2897622509429759 | |
dc.identifier.lattes | 4021286315086194 | |
dc.identifier.lattes | 6914969526213393 | |
dc.identifier.uri | http://hdl.handle.net/11449/16664 | |
dc.identifier.wos | WOS:000307524800006 | |
dc.language.iso | eng | |
dc.publisher | Quintessence Publishing Co Inc | |
dc.relation.ispartof | Journal of Adhesive Dentistry | |
dc.relation.ispartofjcr | 1.691 | |
dc.relation.ispartofsjr | 0,839 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | marginal microleakage | en |
dc.subject | diagnosis | en |
dc.subject | validity of tests | en |
dc.title | Accuracy of Digital Images in the Detection of Marginal Micro leakage: An In Vitro Study | en |
dc.type | Artigo | |
dcterms.license | http://www.quintpub.com/journals/jad/permissions.php | |
dcterms.rightsHolder | Quintessence Publishing Co Inc | |
unesp.author.lattes | 2897622509429759 | |
unesp.author.lattes | 4021286315086194[3] | |
unesp.author.lattes | 6914969526213393[4] | |
unesp.author.orcid | 0000-0002-6768-2670[4] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Odontologia Restauradora - FOAR | pt |
unesp.department | Odontologia Social - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: